Behavior of selenium hydride in heated quartz tube and dielectric barrier discharge atomizers.
Kratzer, Jan; Musil, Stanislav; Marschner, Karel; Svoboda, Milan; Matousek, Tomás; Mester, Zoltán; Sturgeon, Ralph E; Dedina, Jirí.
Afiliação
  • Kratzer J; Czech Academy of Sciences, Institute of Analytical Chemistry, Veverí 97, CZ-602 00, Brno, Czech Republic. Electronic address: jkratzer@biomed.cas.cz.
  • Musil S; Czech Academy of Sciences, Institute of Analytical Chemistry, Veverí 97, CZ-602 00, Brno, Czech Republic.
  • Marschner K; Czech Academy of Sciences, Institute of Analytical Chemistry, Veverí 97, CZ-602 00, Brno, Czech Republic.
  • Svoboda M; Czech Academy of Sciences, Institute of Analytical Chemistry, Veverí 97, CZ-602 00, Brno, Czech Republic.
  • Matousek T; Czech Academy of Sciences, Institute of Analytical Chemistry, Veverí 97, CZ-602 00, Brno, Czech Republic.
  • Mester Z; National Research Council of Canada, 1200 Montreal Road, Ottawa, ON, K1A 0R6, Canada.
  • Sturgeon RE; National Research Council of Canada, 1200 Montreal Road, Ottawa, ON, K1A 0R6, Canada.
  • Dedina J; Czech Academy of Sciences, Institute of Analytical Chemistry, Veverí 97, CZ-602 00, Brno, Czech Republic.
Anal Chim Acta ; 1028: 11-21, 2018 Oct 22.
Article em En | MEDLINE | ID: mdl-29884347
ABSTRACT
Atomization of SeH2 in an externally heated multiple microflame quartz tube atomizer (MMQTA) as well as planar dielectric barrier discharge (DBD) atomizer was investigated using a variety of probes. Deposits of Se on inner surfaces of the atomizers were quantified and their distribution visualized by autoradiography with 75Se radiotracer. The gas phase fraction of Se transported beyond the confines of the atomizers was also determined. In the MMQTA, a 15% mass fraction of Se was deposited in a narrow zone at both colder ends of the optical arm (100-400 °C). By contrast, a 25-40% mass fraction of Se was deposited homogeneously along the entire length of the optical arm of the DBD, depending on detection technique employed. The fraction of Se transported outside the MMQTA approached 90%, whereas it was 50-70% in the DBD. The presence of H2 was essential for atomization of selenium hydride in both atomizers. The gaseous effluent arising from the hydride generator as well as the atomizers was investigated by direct analysis in real time (DART) coupled to an Orbitrap-mass spectrometer, enabling identification of major gas phase species of Se.