Your browser doesn't support javascript.
loading
Value of high-resolution mapping in optimizing cryoballoon ablation of atrial fibrillation.
Conte, Giulio; Soejima, Kyoko; de Asmundis, Carlo; Chierchia, Gian-Battista; Badini, Matteo; Miwa, Yosuke; Caputo, Maria Luce; Özkartal, Tardu; Maffessanti, Francesco; Sieira, Juan; Degreef, Yves; Stroker, Erwin; Regoli, François; Moccetti, Tiziano; Brugada, Pedro; Auricchio, Angelo.
Afiliação
  • Conte G; Division of Cardiology, Cardiocentro Ticino, Lugano, Switzerland. Electronic address: giulio.conte@cardiocentro.org.
  • Soejima K; Department of Cardiology, Kyorin University School of Medicine, Tokyo, Japan.
  • de Asmundis C; Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel - Postgraduate Program Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, Brussels, Belgium.
  • Chierchia GB; Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel - Postgraduate Program Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, Brussels, Belgium.
  • Badini M; Division of Cardiology, Cardiocentro Ticino, Lugano, Switzerland.
  • Miwa Y; Department of Cardiology, Kyorin University School of Medicine, Tokyo, Japan.
  • Caputo ML; Division of Cardiology, Cardiocentro Ticino, Lugano, Switzerland.
  • Özkartal T; Division of Cardiology, Cardiocentro Ticino, Lugano, Switzerland.
  • Maffessanti F; Centre for Computational Medicine in Cardiology, Faculty of Informatics, Università della Svizzera Italiana, Lugano, Switzerland.
  • Sieira J; Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel - Postgraduate Program Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, Brussels, Belgium.
  • Degreef Y; Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel - Postgraduate Program Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, Brussels, Belgium.
  • Stroker E; Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel - Postgraduate Program Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, Brussels, Belgium.
  • Regoli F; Division of Cardiology, Cardiocentro Ticino, Lugano, Switzerland.
  • Moccetti T; Division of Cardiology, Cardiocentro Ticino, Lugano, Switzerland.
  • Brugada P; Heart Rhythm Management Centre, Universitair Ziekenhuis Brussel - Postgraduate Program Cardiac Electrophysiology and Pacing, Vrije Universiteit Brussel, Brussels, Belgium.
  • Auricchio A; Division of Cardiology, Cardiocentro Ticino, Lugano, Switzerland; Centre for Computational Medicine in Cardiology, Faculty of Informatics, Università della Svizzera Italiana, Lugano, Switzerland.
Int J Cardiol ; 270: 136-142, 2018 Nov 01.
Article em En | MEDLINE | ID: mdl-29929934
ABSTRACT

BACKGROUND:

Unrecognized incomplete pulmonary vein isolation (PVI), as opposed to post-PVI pulmonary vein reconnection, may be responsible for clinical recurrences of atrial fibrillation (AF). To date, no data are available on the use of high-resolution mapping (HRM) during cryoballoon (CB) ablation for AF as the index procedure. The aims of this study were - to assess the value of using a HRM system during CB ablation procedures in terms of ability in acutely detecting incomplete CB lesions; - to compare the 8-pole circular mapping catheter (CMC, Achieve) and the 64-pole mini-basket catheter (Orion) with respect to pulmonary vein (PV) signals detection at baseline and after CB ablation; - to characterize the extension of the lesion produced by CB ablation by means of high-density voltage mapping.

METHODS:

Consecutive patients with drug-resistant paroxysmal or early-persistent AF undergoing CB ablation as the index procedure, assisted by a HRM system, were retrospectively included in this study.

RESULTS:

A total of 33 patients (25 males; mean age 59 ±â€¯18 years, 28 paroxysmal AF) were included. At baseline, CMC catheter revealed PV activity in 102 PVs (77%), while the Orion documented PV signals in all veins (100%). Failure of complete CB-PVI was more frequently revealed by atrial re-mapping with the Orion as compared to the Achieve catheter (24% vs 0%, p < 0.05). A repeat ablation was performed in 8 patients (24%). In 9% of cases, the Orion catheter detected far-field signals originating from the right atrium. Quantitative assessment of the created lesion revealed a significant reduction of the left atrial area having voltage >0.5 mV. A total of 29 patients (88%) remained free of symptomatic AF during a mean follow-up of 13.2 ±â€¯3.7 months.

CONCLUSION:

Atrial re-mapping after CB ablation by means of a HRM system improves the detection of areas of incomplete ablation, characterizes the extension of the cryo-ablated tissue and can identify abolishment of potential non-PVI related sources of AF.