Your browser doesn't support javascript.
loading
Patient dose in brain perfusion imaging using an 80-slice CT system.
Messaris, Gerasimos A T; Georgakopoulos, Dimitrios N; Zampakis, Petros; Kalogeropoulou, Christina P; Petsas, Theodoros G; Panayiotakis, George S.
Afiliação
  • Messaris GAT; Department of Medical Physics, School of Medicine, University of Patras, 26504 Patras, Greece.
  • Georgakopoulos DN; Department of Medical Physics, School of Medicine, University of Patras, 26504 Patras, Greece.
  • Zampakis P; Department of Radiology, School of Medicine, University of Patras, 26504 Patras, Greece.
  • Kalogeropoulou CP; Department of Radiology, School of Medicine, University of Patras, 26504 Patras, Greece.
  • Petsas TG; Department of Radiology, School of Medicine, University of Patras, 26504 Patras, Greece.
  • Panayiotakis GS; Department of Medical Physics, School of Medicine, University of Patras, 26504 Patras, Greece. Electronic address: panayiot@upatras.gr.
J Neuroradiol ; 46(4): 243-247, 2019 Jul.
Article em En | MEDLINE | ID: mdl-30030061
BACKGROUND AND PURPOSE: Brain CT Perfusion (CTP) is an X-ray imaging technique for the assessment of brain tissue perfusion, which can be used in several different entities. The aim of this study is the evaluation of the radiation dose to patients during a comprehensive brain CT prescription protocol (CPP) consisting of an unenhanced brain CT, a brain CT angiography and a CTP scan. MATERIALS AND METHODS: Eighteen patients were studied using an 80-slice CT system, with an iterative reconstruction algorithm. The volume Computed Tomography Dose Index (CTDIvol) and dose length product (DLP) were recorded from the dose report of the system. The calculation of effective dose (ED) was accomplished using the DLP values. RESULTS: For the CTP examinations, the CTDIvol ranged from 116.0 to 134.8mGy, with the mean value 119.5mGy. The DLP ranged from 463.9 to 539.2mGy·cm, with the mean value 478mGy·cm. For the CPP, the total ED ranged from 3.31 to 5.07mSv, with the mean value 4.37mSv. CONCLUSIONS: These values are lower than the values reported in corresponding studies, including studies utilizing CT systems with more slices.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doses de Radiação / Encéfalo / Encefalopatias / Tomografia Computadorizada por Raios X / Imagem de Perfusão Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doses de Radiação / Encéfalo / Encefalopatias / Tomografia Computadorizada por Raios X / Imagem de Perfusão Idioma: En Ano de publicação: 2019 Tipo de documento: Article