Your browser doesn't support javascript.
loading
Diagnostic Value of Energy Dispersive Hand-Held X-ray Fluorescence Spectrometry in Determining Trace Element Concentrations in Ovine Liver.
van Loggerenberg, Daniël E; Laver, Pete N; Myburgh, Jan G; Botha, Christo J.
Afiliação
  • van Loggerenberg DE; Department of Paraclinical Sciences, Faculty of Veterinary Science, University of Pretoria, Private Bag X04, Onderstepoort, 0110, South Africa.
  • Laver PN; Department of Biological Sciences, University of Cape Town, Rondebosch, South Africa.
  • Myburgh JG; Department of Paraclinical Sciences, Faculty of Veterinary Science, University of Pretoria, Private Bag X04, Onderstepoort, 0110, South Africa.
  • Botha CJ; Department of Paraclinical Sciences, Faculty of Veterinary Science, University of Pretoria, Private Bag X04, Onderstepoort, 0110, South Africa. christo.botha@up.ac.za.
Biol Trace Elem Res ; 190(2): 358-361, 2019 Aug.
Article em En | MEDLINE | ID: mdl-30315508
ABSTRACT
There are no data available on the use of hand-held X-ray fluorescence (XRF) spectrometry to determine trace element concentrations in veterinary diagnostics. The hand-held XRF spectrometer is easy to use and does not require extensive training for the operator. In Sub-Saharan Africa with few centralised analytical laboratories equipped with expensive apparatus or mass spectrometry capabilities, trace element analysis using the hand-held XRF spectrometer provides an alternative. The objective of this study was to compare ovine hepatic copper (Cu), iron (Fe), manganese (Mn), molybdenum (Mo), selenium (Se) and zinc (Zn) concentrations as obtained with the hand-held XRF spectrometer to those of a reference laboratory using inductively coupled plasma mass spectrometry (ICP-MS). Thirty ovine livers were obtained from an abattoir; prepared as wet blended and oven-dried samples and analysed. Bayesian correlation was used to assess the correspondence between results from the XRF and ICP-MS analyses. The oven-dried preparation procedure for XRF provided the best correlation with the ICP-MS data. The correlations for Cu and Zn were strong and the XRF method may represent a suitable substitute for ICP-MS analysis. For Mn and Fe the correlations were moderately strong and the XRF method may be suitable. For Mo, the correlation was weak and XRF cannot be recommended. Selenium could not be detected in samples prepared by either method. Hand-held XRF spectrometry was a practical method to determine liver concentrations of specific trace elements under African conditions and may significantly reduce the turn-around time of analysis, but unfortunately the apparatus is expensive.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrometria por Raios X / Oligoelementos / Ovinos / Fígado Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrometria por Raios X / Oligoelementos / Ovinos / Fígado Idioma: En Ano de publicação: 2019 Tipo de documento: Article