Your browser doesn't support javascript.
loading
Reliability of diagnosing acute ischemic cerebrovascular on magnetic resonance imaging disorders using iPads.
Hattori, Hidekazu; Kuwayama, Yoshifumi; Inui, Yoshitaka; Murayama, Kazuhiro; Hayakawa, Motoharu; Ito, Shinji; Toyama, Hiroshi.
Afiliação
  • Hattori H; Department of Radiology, Fujita Health University, School of Medicine, 1-98, Dengakugakubo, Kutsukake, Toyoake, Aichi, 470-1192, Japan. hhattori@fujita-hu.ac.jp.
  • Kuwayama Y; Department of Medical Information Systems, Fujita Health University, School of Medicine, Toyoake, Aichi, Japan.
  • Inui Y; Department of Radiology, Fujita Health University, School of Medicine, 1-98, Dengakugakubo, Kutsukake, Toyoake, Aichi, 470-1192, Japan.
  • Murayama K; Department of Radiology, Fujita Health University, School of Medicine, 1-98, Dengakugakubo, Kutsukake, Toyoake, Aichi, 470-1192, Japan.
  • Hayakawa M; Department of Neurosurgery, Fujita Health University, School of Medicine, Toyoake, Aichi, Japan.
  • Ito S; Department of Neurology, Fujita Health University, School of Medicine, Toyoake, Aichi, Japan.
  • Toyama H; Department of Radiology, Fujita Health University, School of Medicine, 1-98, Dengakugakubo, Kutsukake, Toyoake, Aichi, 470-1192, Japan.
Jpn J Radiol ; 36(12): 726-735, 2018 Dec.
Article em En | MEDLINE | ID: mdl-30317411
PURPOSE: The use of tablet terminals has been explored in various medical settings; however, caution should be exercised when performing image diagnosis using this technology. The present study examined the characteristics of an iPad Air™ monitor and assessed radiographic image interpretations to verify the reliability of the telediagnosis of acute cerebral infarction based on magnetic resonance imaging (MRI) using a tablet terminal. MATERIALS AND METHODS: The luminance of the iPad Air™ was measured using a UA-10 analyzer, and radiographic image interpretation experiments were performed in 100 patients who underwent MRI within 6 h of symptom onset. Ten physicians viewed the images on the iPad Air™ and a medical monitor, with an interval of 2 months between each interpretation. RESULTS: When the iPad Air™ screen was pure white, the contour lines revealed nonuniform luminance distribution. In the reading experiment, the areas under the curve of the medical monitor and the iPad Air™ were 0.9311 and 0.9431, respectively. No significant difference was observed between the medical monitor and the iPad Air™ (p = 0.113). CONCLUSION: The results of the observer performance studies for detecting acute ischemic cerebrovascular disorders on an iPad Air™ were found to be similar to those on a medical monitor.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Isquemia Encefálica / Computadores de Mão Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Isquemia Encefálica / Computadores de Mão Idioma: En Ano de publicação: 2018 Tipo de documento: Article