Your browser doesn't support javascript.
loading
A computational tool for simulation and design of tangential multi-energy soft x-ray pin-hole cameras for tokamak plasmas.
Yamazaki, H; Delgado-Aparicio, L F; Groebner, R; Grierson, B; Hill, K; Pablant, N; Stratton, B; Efthimion, P; Ejiri, A; Takase, Y; Ono, M.
Afiliação
  • Yamazaki H; The University of Tokyo, Kashiwa 277-8561, Japan.
  • Delgado-Aparicio LF; Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA.
  • Groebner R; General Atomics, San Diego, California 92121, USA.
  • Grierson B; Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA.
  • Hill K; Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA.
  • Pablant N; Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA.
  • Stratton B; Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA.
  • Efthimion P; Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA.
  • Ejiri A; The University of Tokyo, Kashiwa 277-8561, Japan.
  • Takase Y; The University of Tokyo, Kashiwa 277-8561, Japan.
  • Ono M; Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA.
Rev Sci Instrum ; 89(10): 10G120, 2018 Oct.
Article em En | MEDLINE | ID: mdl-30399783
ABSTRACT
A new tool has been developed to calculate the spectral, spatial, and temporal responses of multi-energy soft x-ray (ME-SXR) pinhole cameras for arbitrary plasma densities (n e,D), temperature (T e), and impurity densities (n Z). ME-SXR imaging provides a unique opportunity for obtaining important plasma properties (e.g., T e, n Z, and Z eff) by measuring both continuum and line emission in multiple energy ranges. This technique employs a pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently. Simulations assuming a tangential geometry and DIII-D-like plasmas (e.g., n e,0 ≈ 8 × 1019 m-3 and T e,0 ≈ 2.8 keV) for various impurity (e.g., C, O, Ar, Ni, and Mo) density profiles have been performed. The computed brightnesses range from few 102 counts pixel-1 ms-1 depending on the cut-off energy thresholds, while the maximum allowable count rate is 104 counts pixel-1 ms-1. The typical spatial resolution in the mid-plane is ≈0.5 cm with a photon-energy resolution of 500 eV at a 500 Hz frame rate.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article