TMS motor mapping: Comparing the absolute reliability of digital reconstruction methods to the golden standard.
Jonker, Zeb D; van der Vliet, Rick; Hauwert, Christopher M; Gaiser, Carolin; Tulen, Joke H M; van der Geest, Jos N; Donchin, Opher; Ribbers, Gerard M; Frens, Maarten A; Selles, Ruud W.
Afiliação
  • Jonker ZD; Department of Neuroscience, Erasmus MC, Rotterdam, the Netherlands; Department of Rehabilitation Medicine, Erasmus MC, Rotterdam, the Netherlands; Rijndam Rehabilitation Center, Rotterdam, the Netherlands. Electronic address: z.jonker@erasmusmc.nl.
  • van der Vliet R; Department of Neuroscience, Erasmus MC, Rotterdam, the Netherlands; Department of Rehabilitation Medicine, Erasmus MC, Rotterdam, the Netherlands.
  • Hauwert CM; Department of Neuroscience, Erasmus MC, Rotterdam, the Netherlands.
  • Gaiser C; Department of Neuroscience, Erasmus MC, Rotterdam, the Netherlands.
  • Tulen JHM; Department of Psychiatry, Erasmus MC, Rotterdam, the Netherlands.
  • van der Geest JN; Department of Neuroscience, Erasmus MC, Rotterdam, the Netherlands.
  • Donchin O; Department of Biomedical Engineering, Ben Gurion University of the Negev, Be'er Sheva, Israel; Zlotowski Center for Neuroscience, Ben Gurion University of the Negev, Be'er Sheva, Israel.
  • Ribbers GM; Department of Rehabilitation Medicine, Erasmus MC, Rotterdam, the Netherlands; Rijndam Rehabilitation Center, Rotterdam, the Netherlands.
  • Frens MA; Department of Neuroscience, Erasmus MC, Rotterdam, the Netherlands; Erasmus University College, Rotterdam, the Netherlands.
  • Selles RW; Department of Rehabilitation Medicine, Erasmus MC, Rotterdam, the Netherlands; Rijndam Rehabilitation Center, Rotterdam, the Netherlands; Department of Plastic and Reconstructive Surgery, Erasmus MC, Rotterdam, the Netherlands.
Brain Stimul ; 12(2): 309-313, 2019.
Article em En | MEDLINE | ID: mdl-30497885
BACKGROUND: Changes in transcranial magnetic stimulation motor map parameters can be used to quantify plasticity in the human motor cortex. The golden standard uses a counting analysis of motor evoked potentials (MEPs) acquired with a predefined grid. Recently, digital reconstruction methods have been proposed, allowing MEPs to be acquired with a faster pseudorandom procedure. However, the reliability of these reconstruction methods has never been compared to the golden standard. OBJECTIVE: To compare the absolute reliability of the reconstruction methods with the golden standard. METHODS: In 21 healthy subjects, both grid and pseudorandom acquisition were performed twice on the first day and once on the second day. The standard error of measurement was calculated for the counting analysis and the digital reconstructions. RESULTS: The standard error of measurement was at least equal using digital reconstructions. CONCLUSION: Pseudorandom acquisition and digital reconstruction can be used in intervention studies without sacrificing reliability.