Your browser doesn't support javascript.
loading
[Thyroglobulin measurement in fine-needle aspiration washout fluid for detection of differentiated thyroid cancer lymph nodes metastases].
Qi, S Y; Deng, L F; Xie, M; Zhu, X Q; Wang, Y F; Liu, X M.
Afiliação
  • Qi SY; Department of Pathology, Jiangxi Provincal Cancer Hospital, Nanchang, 330029, China.
  • Deng LF; Department of Head and Neck Surgery,Jiangxi Provincal Cancer Hospital.
  • Xie M; Department of Pathology, Jiangxi Provincal Cancer Hospital, Nanchang, 330029, China.
  • Zhu XQ; Department of Pathology, Jiangxi Provincal Cancer Hospital, Nanchang, 330029, China.
  • Wang YF; Department of Head and Neck Surgery,Jiangxi Provincal Cancer Hospital.
  • Liu XM; Department of Head and Neck Surgery,Jiangxi Provincal Cancer Hospital.
Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi ; 32(19): 1480-1482, 2018 Oct 05.
Article em Zh | MEDLINE | ID: mdl-30550192
Objective: To investigate the feasibiity of detecting lymph node metastasis in differentiated thyroid cancer patients by thyroglobin(Tg)measurement in fine-needle aspiration washout fluid. Method: Forty-seven differentiated thyroid cancer patients with cervical lymph node metastasis were included in this study. Fine-needle aspirations were performed on lymph nodes which were surgically resected for measurement of Tg in washout fluid. Diagnostic sensitivity, specificity and accuracy were evaluated according to three predetermined Tg threshold values: FNA-Tg/serum Tg>1, 10 ng/ml and 100 ng/ml. Result: The meadian value of FNA-Tg in metastatic lymph node (n=46) was 5 177 ng/ml (1.79-408 300 ng/ml),while lymph node without metastasis (n=11) showed a meadian level of 0.63 ng/ml (0.04-125.4 ng/ml). With the threshold of FNA-Tg level at FNA-Tg/serum Tg>1, 10 ng/ml and 100 ng/ml respectively, the diagnostic sensitivity was 91.3%, 97.83% and 93.48% respectively,the specificity was 81.82%,63.64% and 90.90% respectively,and the accuracy was 89.47%,91.22% and 92.98% respectively. Conclusion: Thyroglobin measurement in fine-needle aspiration washout fluid is effective to diagnose lymph node metastasis in differentiated thyroid cancer.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: Zh Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: Zh Ano de publicação: 2018 Tipo de documento: Article