Surgical outcomes associated with a sutureless drainage valve implantation procedure in patients with refractory glaucoma.
Pham, Caroline N; Radcliffe, Nathan M; Vu, Daniel M.
Afiliação
  • Pham CN; New York University, New York, NY, USA, drradcliffe@gmail.com.
  • Radcliffe NM; New York University, New York, NY, USA, drradcliffe@gmail.com.
  • Vu DM; Weill Cornell Medical College, New York, NY, USA, drradcliffe@gmail.com.
Clin Ophthalmol ; 12: 2607-2615, 2018.
Article em En | MEDLINE | ID: mdl-30587907
ABSTRACT

PURPOSE:

To evaluate the safety and efficacy profile of a sutureless procedure for drainage valve implantation with combined cataract removal and/or endoscopic cyclophotocoagulation (ECP). MATERIALS AND

METHODS:

A retrospective case series study of consecutive surgeries for Ahmed glaucoma valve (AGV; New World Medical) implantation in a 1-year period was analyzed. The surgery was performed using a Tisseel fibrin sealant (Baxter Healthcare Corporation) in place of sutures. Some subsets within the case series also included a cataract extraction with intraocular lens (CEIOL) insertion and/or ECP (Endo Optiks) within the same procedure. Primary outcomes for this study including efficacy (IOP change, reduction in medications) and safety (complications and reoperations) were measured out to 3 years. Comparisons between subsets were made using ANOVA with post hoc Tukey's pairwise tests.

RESULTS:

One hundred twenty-two eyes of 99 patients underwent sutureless AGV implantation surgery. Of the 122, 18 had an AGV implantation only, 46 had an AGV + CEIOL, 35 had an AGV + ECP, and 23 had an AGV + CEIOL + ECP. In total, there was a significant decrease in IOP (P<0.0001) and number of glaucoma medications (P≤0.0054) at each postoperative visit. In a one-way ANOVA, there were no significant differences in mean IOP between the different subsets of surgeries (P>0.05); 10.7% and 14.8% of eyes required a reoperation either for a complication or for uncontrolled glaucoma, respectively.

CONCLUSION:

Sutureless valve implantation is associated with a significant reduction in IOP percentage and medication use after the procedure with a safety profile comparable with other glaucoma surgeries.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article