The MUSHA underactuated hand for robot-aided minimally invasive surgery.
Selvaggio, Mario; Fontanelli, Giuseppe Andrea; Marrazzo, Vincenzo Romano; Bracale, Umberto; Irace, Andrea; Breglio, Giovanni; Villani, Luigi; Siciliano, Bruno; Ficuciello, Fanny.
Afiliação
  • Selvaggio M; Department of Information Technology and Electrical Engineering, University of Naples Federico II, Naples, Italy.
  • Fontanelli GA; Department of Information Technology and Electrical Engineering, University of Naples Federico II, Naples, Italy.
  • Marrazzo VR; Department of Information Technology and Electrical Engineering, University of Naples Federico II, Naples, Italy.
  • Bracale U; Department of Public Health, University of Naples Federico II, Naples, Italy.
  • Irace A; Department of Information Technology and Electrical Engineering, University of Naples Federico II, Naples, Italy.
  • Breglio G; Department of Information Technology and Electrical Engineering, University of Naples Federico II, Naples, Italy.
  • Villani L; Department of Information Technology and Electrical Engineering, University of Naples Federico II, Naples, Italy.
  • Siciliano B; Department of Information Technology and Electrical Engineering, University of Naples Federico II, Naples, Italy.
  • Ficuciello F; Department of Information Technology and Electrical Engineering, University of Naples Federico II, Naples, Italy.
Int J Med Robot ; 15(3): e1981, 2019 Jun.
Article em En | MEDLINE | ID: mdl-30588772
ABSTRACT

BACKGROUND:

Keyhole surgery is characterized by loss of dexterity of surgeon's movements because of the limited workspace, nonintuitive motor skills of the surgical systems, and loss of tactile sensation that may lead to tissue damage and bad execution of the tasks.

METHODS:

In this paper, a three-fingered underactuated miniature tool for robot-aided laparoscopic surgery is presented. The design is conceived to realize a closed-hand configuration allowing the insertion of the tool into the abdominal cavity through the trocar in one step and to reach different grasping as well as pushing/holding configurations once in the cavity.

RESULTS:

Aiming to replicate human hand dexterity and versatility, different solutions for the kinematic structure of the hand are analyzed using quality indices to evaluate the manipulability and stability of the grasp. Furthermore, a first prototype of fingertip force sensor based on fiber Bragg grating (FBG) technology has been realized and tested. The design choices of the prototype are described and discussed with the aid of experiments.

CONCLUSIONS:

The whole concept and the need for such anthropomorphic tool are discussed with surgeons to highlight constraints and potentials in surgical tasks. The feedback by expert surgeons is used to provide specifications and improvements to the kinematics and mechanical design. The investigations of different designs allow identifying the optimal solution to improve grasping and manipulation capabilities. The tests on FBG sensors led to the conclusion that this technology guarantees good performance and can be a good solution for applications in surgical robotics.