Your browser doesn't support javascript.
loading
Impact of procedural characteristics on coronary vessel wall healing following implantation of second-generation drug-eluting absorbable metal scaffold in patients with de novo coronary artery lesions: an optical coherence tomography analysis.
Ozaki, Yuichi; Garcia-Garcia, Hector M; Hideo-Kajita, Alexandre; Kuku, Kayode O; Haude, Michael; Ince, Hüseyin; Abizaid, Alexandre; Tölg, Ralph; Lemos, Pedro Alves; von Birgelen, Clemens; Christiansen, Evald Høj; Wijns, William; Escaned, Javier; Dijkstra, Jouke; Waksman, Ron.
Afiliação
  • Ozaki Y; Section of Interventional Cardiology, MedStar Washington Hospital Center, 110 Irving Street NW, Suite 4B-1, Washington, DC, USA.
  • Garcia-Garcia HM; Section of Interventional Cardiology, MedStar Cardiovascular Research Network, MedStar Washington Hospital Center, Washington, DC, USA.
  • Hideo-Kajita A; Section of Interventional Cardiology, MedStar Washington Hospital Center, 110 Irving Street NW, Suite 4B-1, Washington, DC, USA.
  • Kuku KO; Section of Interventional Cardiology, MedStar Cardiovascular Research Network, MedStar Washington Hospital Center, Washington, DC, USA.
  • Haude M; Section of Interventional Cardiology, MedStar Washington Hospital Center, 110 Irving Street NW, Suite 4B-1, Washington, DC, USA.
  • Ince H; Section of Interventional Cardiology, MedStar Cardiovascular Research Network, MedStar Washington Hospital Center, Washington, DC, USA.
  • Abizaid A; Section of Interventional Cardiology, MedStar Cardiovascular Research Network, MedStar Washington Hospital Center, Washington, DC, USA.
  • Tölg R; Medical Clinic I, Städtische Kliniken Neuss, Lukaskrankenhaus GmbH, Neuss, Germany.
  • Lemos PA; Department of Cardiology, Vivantes Klinikum im Friedrichschain and Am Urban, Berlin, Germany.
  • von Birgelen C; Instituto de Cardiologia Dante Pazzanese, Sao Paulo, Brazil.
  • Christiansen EH; Herzzentrum Segeberger Kliniken GmbH, Bad Segeberg, Germany.
  • Wijns W; Instituto do Coração - HCFMUSP, University of Sao Paulo, São Paulo, Brazil.
  • Escaned J; Department of Cardiology, Medisch Spectrum Twente, Thoraxcentrum Twente, Enschede, the Netherlands.
  • Dijkstra J; Department of Cardiology, Aarhus University Hospital, Skejby, Aarhus, Denmark.
  • Waksman R; Cardiology Department, Cardiovascular Research Center Aalst, OLV Hospital, Aalst, Belgium.
Eur Heart J Cardiovasc Imaging ; 20(8): 916-924, 2019 Aug 01.
Article em En | MEDLINE | ID: mdl-30590578
ABSTRACT

AIMS:

Second-generation drug-eluting absorbable metal scaffold (DREAMS 2G) is an alternative novel device for treating coronary lesions. However, the relationship between in-scaffold dimensions after implantation of DREAMS 2G and vessel healing and luminal results at follow-up is unknown. The aim of this study is, therefore, to investigate whether the expansion index after implantation of DREAMS 2G as assessed by optical coherence tomography (OCT) impacts late luminal status and healing of the vessel wall. METHODS AND

RESULTS:

This study comprises of a total 65 out of 123 patients who were enrolled in the BIOSOLVE-II trial. We assessed both qualitative and quantitative OCT findings and the expansion index of DREAMS 2G after implantation frame by frame using OCT. Expansion index was defined as minimum scaffold area/mean reference lumen area. The over-expansion group was also defined with expansion index >1.0. The total number of analysed frames at post-procedure and 6-month follow-up was 8243 and 8263 frames, respectively. At 6-month follow-up, in-scaffold healing was documented by the reduction of 82% in dissections, 93% in attached intra-luminal mass (ILM), 65% in non-attached ILM, and 76% in jailed side branch. The over-expansion group had significantly greater in-scaffold luminal volume loss (LVL) compared with the non-over-expansion group [over-expansion 35.0 (18.5-52.1) mm3 vs. non-over-expansion 21.0 (11.6-37.9) mm3, P = 0.039].

CONCLUSION:

Excellent in vivo healing process after implantation of DREAMS 2G was observed at 6 months. We found that higher expansion indices were associated with higher in-scaffold LVL at 6 months assessed by OCT.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cicatrização / Vasos Coronários / Tomografia de Coerência Óptica / Stents Farmacológicos Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cicatrização / Vasos Coronários / Tomografia de Coerência Óptica / Stents Farmacológicos Idioma: En Ano de publicação: 2019 Tipo de documento: Article