Your browser doesn't support javascript.
loading
Development of a dual beamlet monitor system for negative ion beam measurements.
Haba, Y; Nagaoka, K; Tsumori, K; Kisaki, M; Nakano, H; Ikeda, K; Fujiwara, Y; Kamio, S; Yoshimura, S; Osakabe, M.
Afiliação
  • Haba Y; Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8602, Japan.
  • Nagaoka K; Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8602, Japan.
  • Tsumori K; National Institute for Fusion Science, National Institutes of Natural Sciences, 322-6 Oroshi-cho, Toki 509-5292, Japan.
  • Kisaki M; National Institute for Fusion Science, National Institutes of Natural Sciences, 322-6 Oroshi-cho, Toki 509-5292, Japan.
  • Nakano H; National Institute for Fusion Science, National Institutes of Natural Sciences, 322-6 Oroshi-cho, Toki 509-5292, Japan.
  • Ikeda K; National Institute for Fusion Science, National Institutes of Natural Sciences, 322-6 Oroshi-cho, Toki 509-5292, Japan.
  • Fujiwara Y; National Institute for Fusion Science, National Institutes of Natural Sciences, 322-6 Oroshi-cho, Toki 509-5292, Japan.
  • Kamio S; National Institute for Fusion Science, National Institutes of Natural Sciences, 322-6 Oroshi-cho, Toki 509-5292, Japan.
  • Yoshimura S; National Institute for Fusion Science, National Institutes of Natural Sciences, 322-6 Oroshi-cho, Toki 509-5292, Japan.
  • Osakabe M; National Institute for Fusion Science, National Institutes of Natural Sciences, 322-6 Oroshi-cho, Toki 509-5292, Japan.
Rev Sci Instrum ; 89(12): 123303, 2018 Dec.
Article em En | MEDLINE | ID: mdl-30599604
To evaluate negative ion beam properties, a dual beamlet monitor system has been developed. The dual beamlet monitor system has two diagnostics in one hexagonal box. One diagnostic is a "fast beamlet monitor" for measuring the time evolution of beamlet current profiles with the time resolution of up to 25 MHz. The other diagnostic is a "pepper-pot-type phase space analyzer," which is applied for the evaluation of a phase space structure of the negative ion beamlet. The dual beamlet monitor system is applied to the measurement of the beamlet in the Neutral Beam Test Stand at National Institute for Fusion Science (NIFS-NBTS), in which the beam accelerator is almost identical to those of working beam injectors in the large helical device. It is demonstrated that the overlapping components from the neighboring beamlet can be eliminated, and the phase space structure can be obtained for the single beamlet.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2018 Tipo de documento: Article