Evaluation of quality of life after implantation of a new trifocal intraocular lens.
Akman, Ahmet; Asena, Leyla; Ozturk, Caner; Gür Güngör, Sirel.
Afiliação
  • Akman A; Baskent University Faculty of Medicine, Department of Ophthalmology, Ankara, Turkey.
  • Asena L; Baskent University Faculty of Medicine, Department of Ophthalmology, Ankara, Turkey. Electronic address: leylaerk@yahoo.com.
  • Ozturk C; Baskent University Faculty of Medicine, Department of Ophthalmology, Ankara, Turkey.
  • Gür Güngör S; Baskent University Faculty of Medicine, Department of Ophthalmology, Ankara, Turkey.
J Cataract Refract Surg ; 45(2): 130-134, 2019 02.
Article em En | MEDLINE | ID: mdl-30612749
ABSTRACT

PURPOSE:

To evaluate the vision-related quality of life (QOL) after implantation of a new trifocal intraocular lens (IOL), by using the National Eye Institute Visual Function Questionnaire-14 (VF-14 QOL questionnaire).

SETTING:

Baskent University Faculty of Medicine, Department of Ophthalmology, Ankara, Turkey.

DESIGN:

Prospective noncomparative case series.

METHODS:

Consecutive patients who had a new trifocal IOL (PanOptix) bilaterally implanted were included in the study. The vision-related QOL was assessed 3 months after the surgery in the second eye. The VF-14 QOL questionnaire was used, with a grading scale of 0, no difficulty; 1, a little difficulty; 2, moderate difficulty; 3, quite difficult; 4, impossible to perform. A subgroup of 14 patients, with an interval of at least 3 months between the surgery in the first eye and the surgery in the fellow eye, were also interviewed 3 months after the monocular IOL implantation. In this subgroup, the QOL with monocular and binocular implantation was compared.

RESULTS:

The study comprised 48 patients. Reading small print, driving at night, and doing fine handwork were the most difficult tasks to perform, with the mean values of the VF-14 QOL questionnaire being 0.94 ± 0.81 (SD), 0.89 ± 0.68, and 0.64 ± 0.67, respectively. Binocular implantation was associated with improvement in vision-related QOL when compared with monocular implantation, with significant differences in doing fine handwork such as sewing (P = .02) and using a computer (P = .03).

CONCLUSIONS:

With mean values of 1.00 or lower for each question, the results of the VF-14 QOL questionnaire indicated that patients who have the new trifocal IOL bilaterally implanted have an overall high satisfaction rate and a high vision-related QOL.