Development of a novel biofilm classification tool and comparative analysis of result interpretation methodologies for the evaluation of biofilm forming capacity of bacteria using tissue culture plate method.
Avdic, Monia; Dzuzic, Nermin; Hasanic, Osman; Spahic, Amel; Smajlovic Skenderagic, Lejla; Badnjevic, Almir; Hukic, Mirsada.
Afiliação
  • Avdic M; International Burch University, Sarajevo, Bosnia and Herzegovina.
  • Dzuzic N; International Burch University, Sarajevo, Bosnia and Herzegovina.
  • Hasanic O; International Burch University, Sarajevo, Bosnia and Herzegovina.
  • Spahic A; Mistral Technologies, Sarajevo, Bosnia and Herzegovina.
  • Smajlovic Skenderagic L; International Burch University, Sarajevo, Bosnia and Herzegovina.
  • Badnjevic A; International Burch University; Verlab Ltd, Sarajevo, Bosnia and Herzegovina.
  • Hukic M; Institute for Biomedical Diagnostics and Research NALAZ; Academy of Sciences and Arts of Bosnia and Herzegovina, Sarajevo, Bosnia and Herzegovina.
Med Glas (Zenica) ; 16(1): 13-21, 2019 Feb 01.
Article em En | MEDLINE | ID: mdl-30680979
ABSTRACT
Aim To develop an online biofilm calculation tool (Biofilm Classifier), which calculates the optical density cut off value and accordingly determines the biofilm forming categories for the tested isolates by standardized formulas, as well as to compare the results obtained by Biofilm Classifier to manual calculations and the use of predefined values. Methods The biofilm forming capacity of tested strains was evaluated using tissue culture plate method in 96 well plates, and optical density (OD) value of the formed biofilm was measured on an ELISA Microplate reader at 595 nm on a total of 551 bacterial isolates from clinical specimen. Results Comparative analysis indicated that the manual calculation was 100% in accordance with results obtained by the designed software as opposed to the results obtained by use of predefined values for biofilm categorization. When using predefined values compared to manual biofilm categorization for the determination of biofilm positive and biofilm negative strains the specificity was 100%, sensitivity 97.81%, positive predictive value 100%, negative predictive value 96.04% and accuracy 98.57%. Conclusion Considering obtained results, the use of the designed online calculator would simplify the interpretation of biofilm forming capacity of bacteria using tissue culture plate method.