Your browser doesn't support javascript.
loading
Quantitation of free and total N-acetylcysteine amide and its metabolite N-acetylcysteine in human plasma using derivatization and electrospray LC-MS/MS.
King, Brad; Vance, Jennifer; Wall, G Michael; Shoup, Ronald.
Afiliação
  • King B; AIT Bioscience, LLC, 7840 Innovation Blvd, Indianapolis, IN 46278, USA.
  • Vance J; AIT Bioscience, LLC, 7840 Innovation Blvd, Indianapolis, IN 46278, USA.
  • Wall GM; Nacuity Pharmaceuticals, Inc., 306 W 7th Street, Suite 310, Ft Worth, TX 76102, USA.
  • Shoup R; AIT Bioscience, LLC, 7840 Innovation Blvd, Indianapolis, IN 46278, USA. Electronic address: rshoup@aitbioscience.com.
Article em En | MEDLINE | ID: mdl-30708342
ABSTRACT
Studies of N-acetylcysteine amide (NACA) in nonclinical models have demonstrated various antioxidant, anti-apoptotic, anti-inflammatory and neuroprotective effects, and it is currently being developed as a treatment for retinitis pigmentosa. Sensitive LC-MS/MS methods were developed and validated to quantitate reduced and total NACA and its major metabolite, N-acetylcysteine (NAC), in human plasma to support clinical studies involving NACA. To trap and stabilize reduced NACA and NAC at the time of collection, whole blood was immediately treated with 2-chloro-1-methylpyridinium iodide (CMPI) to convert free thiols to 1-methylpyridinyl thioether derivatives. Plasma was harvested and frozen until samples were assayed using protein precipitation and an LC-MS/MS separation based on hydrophilic-interaction chromatography (HILIC). To process NACA and NAC present as disulfides, an intermediate portion of the extract was further subjected to reduction with tris(2-carboxyethyl) phosphine; the released thiols were then reacted with CMPI, extracted, and analyzed as before, to measure total thiols. The method for NACA and NAC, whether free/reduced or total, covered a range from 50 ng/mL to 50 µg/mL in human plasma and required a single 25 µL plasma sample. Up to 180 samples could be assayed in a single session. The inter-run mean bias and precision (%CV) were within ±5% for the free thiol method and within ±8.5% for the total thiol method. Benchtop, freeze/thaw, and long-term stability were evaluated and acceptable. The NAC/NACA method applied to a clinical study demonstrated incurred sample reproducibility of 95.5% for NAC and 99.1% for NACA.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Acetilcisteína / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Acetilcisteína / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas em Tandem Idioma: En Ano de publicação: 2019 Tipo de documento: Article