Your browser doesn't support javascript.
loading
Indoor particulate matter and lung function in children.
Isiugo, Kelechi; Jandarov, Roman; Cox, Jennie; Ryan, Patrick; Newman, Nicholas; Grinshpun, Sergey A; Indugula, Reshmi; Vesper, Steven; Reponen, Tiina.
Afiliação
  • Isiugo K; Department of Environmental Health, University of Cincinnati, Cincinnati, OH, USA.
  • Jandarov R; Department of Environmental Health, University of Cincinnati, Cincinnati, OH, USA.
  • Cox J; Department of Environmental Health, University of Cincinnati, Cincinnati, OH, USA.
  • Ryan P; Department of Environmental Health, University of Cincinnati, Cincinnati, OH, USA; University of Cincinnati, Department of Pediatrics, Cincinnati, OH, USA.
  • Newman N; Department of Environmental Health, University of Cincinnati, Cincinnati, OH, USA; University of Cincinnati, Department of Pediatrics, Cincinnati, OH, USA.
  • Grinshpun SA; Department of Environmental Health, University of Cincinnati, Cincinnati, OH, USA.
  • Indugula R; Department of Environmental Health, University of Cincinnati, Cincinnati, OH, USA.
  • Vesper S; United States Environmental Protection Agency, USA.
  • Reponen T; Department of Environmental Health, University of Cincinnati, Cincinnati, OH, USA. Electronic address: Tiina.Reponen@uc.edu.
Sci Total Environ ; 663: 408-417, 2019 May 01.
Article em En | MEDLINE | ID: mdl-30716631
ABSTRACT
People generally spend more time indoors than outdoors resulting in a higher proportion of exposure to particulate matter (PM) occurring indoors. Consequently, indoor PM levels, in contrast to outdoor PM levels, may have a stronger relationship with lung function. To test this hypothesis, indoor and outdoor PM2.5 and fungal spore data were simultaneously collected from the homes of forty-four asthmatic children aged 10-16 years. An optical absorption technique was utilized on the collected PM2.5 mass to obtain concentrations of black carbon (BC) and ultraviolet light absorbing particulate matter, (UVPM; a marker of light absorbing PM2.5 emitted from smoldering organics). Enrolled children completed spirometry after environmental measurements were made. Given the high correlation between PM2.5, BC, and UVPM, principal component analysis was used to obtain uncorrelated summaries of the measured PM. Separate linear mixed-effect models were developed to estimate the association between principal components of the PM variables and spirometry values, as well as the uncorrelated original PM variables and spirometry values. A one-unit increase in the first principal component variable representing indoor PM (predominantly composed of UVPM and PM2.5) was associated with 4.1% decrease (99% CI = -6.9, -1.4) in FEV1/FVC ratio. 11.3 µg/m3 increase in indoor UVPM was associated with 6.4% and 14.7% decrease (99% CI = -10.4, -2.4 and 99% CI = -26.3, -2.9, respectively) in percent predicted FEV1/FVC ratio and FEF25-75 respectively. Additionally, 17.7 µg/m3 increase in indoor PM2.5 was associated with 6.1% and 12.9% decrease (99% CI = -10.2, -1.9 and 99% CI = -24.9, -1.0, respectively) in percent predicted FEV1/FVC ratio and FEF25-75, respectively. Outdoor PM, indoor BC, and indoor fungal spores were not significantly associated with lung function. The results indicate that indoor PM is more strongly associated with lung function in children with asthma as compared with outdoor PM.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Monitoramento Ambiental / Poluição do Ar em Ambientes Fechados / Poluentes Atmosféricos / Material Particulado Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Monitoramento Ambiental / Poluição do Ar em Ambientes Fechados / Poluentes Atmosféricos / Material Particulado Idioma: En Ano de publicação: 2019 Tipo de documento: Article