Your browser doesn't support javascript.
loading
Trends in cardiorespiratory fitness: The evolution of exercise treadmill testing at a single Academic Medical Center from 1970 to 2012.
Kelly, Jacob P; Andonian, Brian J; Patel, Mahesh J; Huang, Zhen; Shaw, Linda K; McGarrah, Robert W; Borges-Neto, Salvador; Velazquez, Eric J; Kraus, William E.
Afiliação
  • Kelly JP; Duke Clinical Research Institute, Duke Medicine, Durham, NC; Division of Cardiology, Department of Medicine, Duke University School of Medicine, Durham, NC.
  • Andonian BJ; Duke Molecular Physiology Institute, Durham, NC. Electronic address: brian.andonian@duke.edu.
  • Patel MJ; Division of Cardiology, Department of Medicine, Duke University School of Medicine, Durham, NC; Merck Research Laboratories, Rahway, NJ.
  • Huang Z; Duke Clinical Research Institute, Duke Medicine, Durham, NC.
  • Shaw LK; Duke Clinical Research Institute, Duke Medicine, Durham, NC.
  • McGarrah RW; Division of Cardiology, Department of Medicine, Duke University School of Medicine, Durham, NC; Duke Molecular Physiology Institute, Durham, NC.
  • Borges-Neto S; Division of Cardiology, Department of Medicine, Duke University School of Medicine, Durham, NC; Division of Nuclear Medicine, Department of Radiology, Durham, NC.
  • Velazquez EJ; Duke Clinical Research Institute, Duke Medicine, Durham, NC; Division of Cardiology, Department of Medicine, Duke University School of Medicine, Durham, NC.
  • Kraus WE; Duke Clinical Research Institute, Duke Medicine, Durham, NC; Division of Cardiology, Department of Medicine, Duke University School of Medicine, Durham, NC; Duke Molecular Physiology Institute, Durham, NC.
Am Heart J ; 210: 88-97, 2019 04.
Article em En | MEDLINE | ID: mdl-30743212
OBJECTIVE: To identify temporal trends in the use of exercise treadmill testing (ETT) and cardiorespiratory fitness (CRF) estimated by ETT in metabolic equivalents (METs). PATIENTS AND METHODS: We compiled an ETT database of all available treadmill tests-including those with concomitant stress echocardiography and nuclear perfusion imaging studies-performed at Duke University Hospital from January 1, 1970- December 31, 2012. Six different ramp protocols were used in these combined modalities. CRF at maximal exertion was estimated using established metrics. Eligible patients were required to have no missing data on maximal treadmill speed, grade, and protocol. RESULTS: The most commonly used ETT protocol was the Bruce (n = 28,877), followed by manual test (n = 7390). Since the 1980's, the use of ETT for clinical purposes declined substantially; there was a decreased trend in utilization of 9.4% over the decades 1990-1999 and 2000-2009. When standard protocol (Bruce) was assessed in isolation, trends in CRF decreased progressively from 1970 to 2012 (mean METs (standard deviation): 11.7 (4.3) to 10.5 (3.5)). After adjusting for baseline comorbidities, the trend was reduced to a lesser degree. CONCLUSIONS: The use of ETT at our institution has declined over time, perhaps due to changes in clinical practice. In patients undergoing ETT using the standard Bruce protocol, CRF decreased progressively over the last five decades. Future studies are needed to clarify the etiology of the decrease in use of such a powerful predictor of clinical outcomes in our medical care environment.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Troca Gasosa Pulmonar / Aptidão Física / Metabolismo Energético / Teste de Esforço Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Troca Gasosa Pulmonar / Aptidão Física / Metabolismo Energético / Teste de Esforço Idioma: En Ano de publicação: 2019 Tipo de documento: Article