Your browser doesn't support javascript.
loading
In vivo ratiometric optical mapping enables high-resolution cardiac electrophysiology in pig models.
Lee, Peter; Quintanilla, Jorge G; Alfonso-Almazán, José M; Galán-Arriola, Carlos; Yan, Ping; Sánchez-González, Javier; Pérez-Castellano, Nicasio; Pérez-Villacastín, Julián; Ibañez, Borja; Loew, Leslie M; Filgueiras-Rama, David.
Afiliação
  • Lee P; Essel Research and Development Inc., Toronto, 337 Sheppard Ave East, Toronto, Ontario M2N 3B3, Canada.
  • Quintanilla JG; Spanish National Cardiovascular Research Center, Carlos III (CNIC), Myocardial Pathophysiology Area, Melchor Fernández Almagro, 3, Madrid, Spain.
  • Alfonso-Almazán JM; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Av. Monforte de Lemos 3-5, Madrid, Spain.
  • Galán-Arriola C; Arrhythmia Unit, Cardiovascular Institute, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Prof. Martín Lagos s/n, Madrid, Spain.
  • Yan P; Spanish National Cardiovascular Research Center, Carlos III (CNIC), Myocardial Pathophysiology Area, Melchor Fernández Almagro, 3, Madrid, Spain.
  • Sánchez-González J; Spanish National Cardiovascular Research Center, Carlos III (CNIC), Myocardial Pathophysiology Area, Melchor Fernández Almagro, 3, Madrid, Spain.
  • Pérez-Castellano N; Richard D. Berlin Center for Cell Analysis and Modeling, University of Connecticut School of Medicine, 263 Farmington Avenue, Farmington, CT, USA.
  • Pérez-Villacastín J; Philips Healthcare Iberia, María de Portugal 1, Madrid, Spain.
  • Ibañez B; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Av. Monforte de Lemos 3-5, Madrid, Spain.
  • Loew LM; Arrhythmia Unit, Cardiovascular Institute, Instituto de Investigación Sanitaria del Hospital Clínico San Carlos (IdISSC), Prof. Martín Lagos s/n, Madrid, Spain.
  • Filgueiras-Rama D; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Av. Monforte de Lemos 3-5, Madrid, Spain.
Cardiovasc Res ; 115(11): 1659-1671, 2019 09 01.
Article em En | MEDLINE | ID: mdl-30753358
ABSTRACT

AIMS:

Cardiac optical mapping is the gold standard for measuring complex electrophysiology in ex vivo heart preparations. However, new methods for optical mapping in vivo have been elusive. We aimed at developing and validating an experimental method for performing in vivo cardiac optical mapping in pig models. METHODS AND

RESULTS:

First, we characterized ex vivo the excitation-ratiometric properties during pacing and ventricular fibrillation (VF) of two near-infrared voltage-sensitive dyes (di-4-ANBDQBS/di-4-ANEQ(F)PTEA) optimized for imaging blood-perfused tissue (n = 7). Then, optical-fibre recordings in Langendorff-perfused hearts demonstrated that ratiometry permits the recording of optical action potentials (APs) with minimal motion artefacts during contraction (n = 7). Ratiometric optical mapping ex vivo also showed that optical AP duration (APD) and conduction velocity (CV) measurements can be accurately obtained to test drug effects. Secondly, we developed a percutaneous dye-loading protocol in vivo to perform high-resolution ratiometric optical mapping of VF dynamics (motion minimal) using a high-speed camera system positioned above the epicardial surface of the exposed heart (n = 11). During pacing (motion substantial) we recorded ratiometric optical signals and activation via a 2D fibre array in contact with the epicardial surface (n = 7). Optical APs in vivo under general anaesthesia showed significantly faster CV [120 (63-138) cm/s vs. 51 (41-64) cm/s; P = 0.032] and a statistical trend to longer APD90 [242 (217-254) ms vs. 192 (182-233) ms; P = 0.095] compared with ex vivo measurements in the contracting heart. The average rate of signal-to-noise ratio (SNR) decay of di-4-ANEQ(F)PTEA in vivo was 0.0671 ± 0.0090 min-1. However, reloading with di-4-ANEQ(F)PTEA fully recovered the initial SNR. Finally, toxicity studies (n = 12) showed that coronary dye injection did not generate systemic nor cardiac damage, although di-4-ANBDQBS injection induced transient hypotension, which was not observed with di-4-ANEQ(F)PTEA.

CONCLUSIONS:

In vivo optical mapping using voltage ratiometry of near-infrared dyes enables high-resolution cardiac electrophysiology in translational pig models.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fibrilação Ventricular / Potenciais de Ação / Técnicas Eletrofisiológicas Cardíacas / Imagens com Corantes Sensíveis à Voltagem / Corantes Fluorescentes / Frequência Cardíaca Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fibrilação Ventricular / Potenciais de Ação / Técnicas Eletrofisiológicas Cardíacas / Imagens com Corantes Sensíveis à Voltagem / Corantes Fluorescentes / Frequência Cardíaca Idioma: En Ano de publicação: 2019 Tipo de documento: Article