Your browser doesn't support javascript.
loading
A Parts Per Billion (ppb) Sensor for NO2 with Microwatt (µW) Power Requirements Based on Micro Light Plates.
Casals, Olga; Markiewicz, Nicolai; Fabrega, Cristian; Gràcia, Isabel; Cané, Carles; Wasisto, Hutomo Suryo; Waag, Andreas; Prades, Joan Daniel.
Afiliação
  • Casals O; MIND-IN2UB, Department of Electronic and Biomedical Engineering , Universitat de Barcelona , E-08028 Barcelona , Spain.
  • Markiewicz N; MIND-IN2UB, Department of Electronic and Biomedical Engineering , Universitat de Barcelona , E-08028 Barcelona , Spain.
  • Fabrega C; MIND-IN2UB, Department of Electronic and Biomedical Engineering , Universitat de Barcelona , E-08028 Barcelona , Spain.
  • Gràcia I; IMB-CNM (CSIC) , Institut de Microelectrònica de Barcelona , Campus UAB, E-08193 Bellaterra , Spain.
  • Cané C; IMB-CNM (CSIC) , Institut de Microelectrònica de Barcelona , Campus UAB, E-08193 Bellaterra , Spain.
  • Prades JD; MIND-IN2UB, Department of Electronic and Biomedical Engineering , Universitat de Barcelona , E-08028 Barcelona , Spain.
ACS Sens ; 4(4): 822-826, 2019 04 26.
Article em En | MEDLINE | ID: mdl-30758185
ABSTRACT
A film of gas sensitive ZnO nanoparticles has been coupled with a low-power micro light plate (µLP) to achieve a NO2-parts-per-billion conductometric gas sensor operating at room temperature. In this µLP configuration, an InGaN-based LED (emitting at 455 nm) is integrated at a few hundred nanometers distance from the sensor material, leading to sensor photoactivation with well controlled, uniform, and high irradiance conditions, and very low electrical power needs. The response curves to different NO2 concentrations as a function of the irradiance displayed a bell-like shape. Responses of 20% to 25 ppb of NO2 were already observed at irradiances of 5 mWatts·cm-2 (applying an electrical power as low as 30 µW). In the optimum illumination conditions (around 60 mWatts·cm-2, or 200 µW of electric power), responses of 94% to 25 ppb were achieved, corresponding to a lower detection limit of 1 ppb of NO2. Higher irradiance values worsened the sensor response in the parts-per-billion range of NO2 concentrations. The responses to other gases such as NH3, CO, and CH4 were much smaller, showing a certain selectivity toward NO2. The effects of humidity on the sensor response are also discussed.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Atmosféricos / Técnicas Eletroquímicas / Dióxido de Nitrogênio Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Atmosféricos / Técnicas Eletroquímicas / Dióxido de Nitrogênio Idioma: En Ano de publicação: 2019 Tipo de documento: Article