Your browser doesn't support javascript.
loading
High sensitive single chain variable fragment screening from a microcystin-LR immunized mouse phage antibody library and its application in immunoassay.
Xu, Chongxin; Liu, Xiaoqin; Liu, Yuan; Zhang, Xiao; Zhang, Cunzheng; Li, Jianhong; Liu, Xianjin.
Afiliação
  • Xu C; Laboratory for Food Quality and Safety-State Key Laboratory Cultivation Base of Ministry of Science and Technology, Institute of Food Safety and Nutrition, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China; College of Life Sciences, Nanjing Normal University, Nanjing 210023, China.
  • Liu X; Huaihua Vocational and Technical College, Huaihua 418007, China.
  • Liu Y; Laboratory for Food Quality and Safety-State Key Laboratory Cultivation Base of Ministry of Science and Technology, Institute of Food Safety and Nutrition, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China.
  • Zhang X; Laboratory for Food Quality and Safety-State Key Laboratory Cultivation Base of Ministry of Science and Technology, Institute of Food Safety and Nutrition, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China.
  • Zhang C; Laboratory for Food Quality and Safety-State Key Laboratory Cultivation Base of Ministry of Science and Technology, Institute of Food Safety and Nutrition, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China.
  • Li J; College of Life Sciences, Nanjing Normal University, Nanjing 210023, China. Electronic address: lijianhong@njnu.edu.cn.
  • Liu X; Laboratory for Food Quality and Safety-State Key Laboratory Cultivation Base of Ministry of Science and Technology, Institute of Food Safety and Nutrition, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China. Electronic address: jaasliu@jaas.ac.cn.
Talanta ; 197: 397-405, 2019 May 15.
Article em En | MEDLINE | ID: mdl-30771953
Microcystin-LR (MC-LR) is one of common high-toxic biotoxins produced by cyanobacteria in waterbody. A high sensitive and convenient detection method is necessary for monitoring for MC-LR. To establish a high sensitive indirect competitive enzyme-linked immunosorbent assay (IC-ELISA) based on single chain variable fragment (scFv) for detecting MC-LR, 16 positive anti-MC-LR phage scFv particles were screened out from a MC-LR-immunized mouse phage scFv library, which was successfully constructed with the capacity of 8.67 × 107 CFU/mL. The most positive anti-MC-LR phage scFv (MscFv7) was successfully expressed in Escherichia coli (E.coli) HB2151. The molecular weight (M.W.) of expressed protein was about 30 kDa, and the concentration of purified protein was 512.6 µg/mL analyzed by SDS-PAGE and protein quantitative respectively. The IC-ELISA based on MscFv7-scFv for MC-LR shows a half-maximum inhibition (IC50) of 0.471 µg/L and a limit of detection (LOD) of 0.044 µg/L, which is below the maximum residue limit standard (MRLs) of 1.0 µg/L in drinking water. The MscFv7-scFv has a strong cross-recognition for MC-RR and MC-YR with cross-reactivity (CRs) of 93.1% and 85.9%, respectively, but weak for MC-LW with that of 9.7%, even non-recognition for MC-WR, MC-LF and MC-LY. The recovery rates of IC-ELISA to detect MC-LR spiked in different cleanliness of water samples were 81.2-106.3% with CVs of 2.62-10.22% at intra-assay and inter-assay. The results showed that we obtained a high sensitive anti-MC-LR scFv, and the established IC-ELISA based on MscFv7-scFv should be promising for ultrasensitive monitoring MC-LR, MC-RR and MC-YR in water samples.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Bacteriófagos / Ensaio de Imunoadsorção Enzimática / Microcistinas / Anticorpos Monoclonais Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Bacteriófagos / Ensaio de Imunoadsorção Enzimática / Microcistinas / Anticorpos Monoclonais Idioma: En Ano de publicação: 2019 Tipo de documento: Article