CT temporal subtraction improves early detection of bone metastases compared to SPECT.
Eur Radiol
; 29(10): 5673-5681, 2019 Oct.
Article
em En
| MEDLINE
| ID: mdl-30888486
OBJECTIVES: To compare observer performance of detecting bone metastases between bone scintigraphy, including planar scan and single-photon emission computed tomography, and computed tomography (CT) temporal subtraction (TS). METHODS: Data on 60 patients with cancer who had undergone CT (previous and current) and bone scintigraphy were collected. Previous CT images were registered to the current ones by large deformation diffeomorphic metric mapping; the registered previous images were subtracted from the current ones to produce TS. Definitive diagnosis of bone metastases was determined by consensus between two radiologists. Twelve readers independently interpreted the following pairs of examinations: NM-pair, previous and current CTs and bone scintigraphy, and TS-pair, previous and current CTs and TS. The readers assigned likelihood levels to suspected bone metastases for diagnosis. Sensitivity, number of false positives per patient (FPP), and reading time for each pair of examinations were analysed for evaluating observer performance by performing the Wilcoxon signed-rank test. Figure-of-merit (FOM) was calculated using jackknife alternative free-response receiver operating characteristic analysis. RESULTS: The sensitivity of TS was significantly higher than that of bone scintigraphy (54.3% vs. 41.3%, p = 0.006). FPP with TS was significantly higher than that with bone scintigraphy (0.189 vs. 0.0722, p = 0.003). FOM of TS tended to be better than that of bone scintigraphy (0.742 vs. 0.691, p = 0.070). CONCLUSION: Sensitivity of TS in detecting bone metastasis was significantly higher than that of bone scintigraphy, but still limited to 54%. TS might be superior to bone scintigraphy for early detection of bone metastasis. KEY POINTS: ⢠Computed tomography temporal subtraction was helpful in early detection of bone metastases. ⢠Sensitivity for bone metastasis was higher for computed tomography temporal subtraction than for bone scintigraphy. ⢠Figure-of-merit of computed tomography temporal subtraction was better than that of bone scintigraphy.
Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Neoplasias Ósseas
/
Processamento de Imagem Assistida por Computador
/
Tomografia Computadorizada por Raios X
/
Tomografia Computadorizada de Emissão de Fóton Único
/
Detecção Precoce de Câncer
Idioma:
En
Ano de publicação:
2019
Tipo de documento:
Article