Your browser doesn't support javascript.
loading
Quantification of estradiol cypionate in plasma by liquid chromatography coupled with tandem mass spectrometry: Application in a pharmacokinetic study in healthy female volunteers.
Martins, Roberto Salvador; Antunes, Natalícia J; Comerlatti, Guilherme; Caraccio, Gabriela; Moreno, Ronilson A; Frecentese, Francesco; Caliendo, Giuseppe; De Nucci, Gilberto.
Afiliação
  • Martins RS; Department of Pharmacology, Faculty of Medical Sciences, State University of Campinas (UNICAMP), Campinas, SP, Brazil; Faculty of Medicine Sao Leopoldo Mandic, Campinas, SP, Brazil.
  • Antunes NJ; Department of Pharmacology, Faculty of Medical Sciences, State University of Campinas (UNICAMP), Campinas, SP, Brazil. Electronic address: nataliciaja@gmail.com.
  • Comerlatti G; Faculty of Medicine, University of Mogi das Cruzes, Mogi das Cruzes, Brazil.
  • Caraccio G; Santa Marcelina Medical School, São Paulo, Brazil.
  • Moreno RA; Department of Pharmacology, Faculty of Medical Sciences, State University of Campinas (UNICAMP), Campinas, SP, Brazil.
  • Frecentese F; Department of Pharmacy, School of Medicine, University of Naples Federico II, Naples, Italy.
  • Caliendo G; Department of Pharmacy, School of Medicine, University of Naples Federico II, Naples, Italy.
  • De Nucci G; Department of Pharmacology, Faculty of Medical Sciences, State University of Campinas (UNICAMP), Campinas, SP, Brazil; Faculty of Medicine Sao Leopoldo Mandic, Campinas, SP, Brazil; Faculty of Medicine, University of Mogi das Cruzes, Mogi das Cruzes, Brazil.
J Pharm Biomed Anal ; 170: 273-278, 2019 Jun 05.
Article em En | MEDLINE | ID: mdl-30947128
ABSTRACT
The combination of medroxyprogesterone acetate 25 mg + estradiol cypionate 5 mg is a highly effective, monthly injectable contraceptive. For the first time, this study presents the development and validation of a sensitive method for estradiol cypionate analysis in human plasma by liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Aliquots (500 µL) of plasma were extracted with ethyl ether (100%) and derivatized with dansyl chloride. Its separation was performed on a Jones Chromatography Genesis C8 column and the quantification was performed with a mass spectrometer equipped with an electrospray interface operating in negative ion mode. The run time was 6 min and the calibration curve was linear over the range of 0.005-0.15 ng/mL. The method was applied to evaluate the pharmacokinetics of estradiol cypionate in plasma collected up to 1008 h (42 days) after a single intramuscular administration of 25 mg/mL medroxyprogesterone acetate +5 mg/mL estradiol cypionate to healthy female volunteers (n = 12). The estradiol cypionate maximum plasma concentration (Cmax) was 0.14 ± 0.08 ng/mL reached at 16.83 ± 21.07 h and the area under the plasma concentration versus time curve (AUC0-last) was 14.07 ± 6.32 ng.h/mL. Elimination half-life (t½), apparent volume of distribution (Vd/F), apparent clearance (CL/F) and mean residence time (MRT) were 89.65 ± 76.04 h, 28038 ± 9636 L, 49.02 ± 10.62 L/h and 576.05 ± 238.32 h, respectively, showing that the estradiol cypionate release from the administration site was prolonged and there was no drug accumulation.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Plasma / Estradiol Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Plasma / Estradiol Idioma: En Ano de publicação: 2019 Tipo de documento: Article