Your browser doesn't support javascript.
loading
Removing arsenic from water by coprecipitation with iron: Effect of arsenic and iron concentrations and adsorbent incorporation.
Nur, Tanjina; Loganathan, Paripurnanda; Ahmed, Mohammad Boshir; Johir, Md Abu Hasan; Nguyen, Tien Vinh; Vigneswaran, Saravanamuthu.
Afiliação
  • Nur T; Faculty of Engineering, University of Technology Sydney (UTS), P.O. Box 123, Broadway, NSW, 2007, Australia.
  • Loganathan P; Faculty of Engineering, University of Technology Sydney (UTS), P.O. Box 123, Broadway, NSW, 2007, Australia.
  • Ahmed MB; Faculty of Engineering, University of Technology Sydney (UTS), P.O. Box 123, Broadway, NSW, 2007, Australia.
  • Johir MAH; Faculty of Engineering, University of Technology Sydney (UTS), P.O. Box 123, Broadway, NSW, 2007, Australia.
  • Nguyen TV; Faculty of Engineering, University of Technology Sydney (UTS), P.O. Box 123, Broadway, NSW, 2007, Australia.
  • Vigneswaran S; Faculty of Engineering, University of Technology Sydney (UTS), P.O. Box 123, Broadway, NSW, 2007, Australia. Electronic address: s.vigneswaran@uts.edu.au.
Chemosphere ; 226: 431-438, 2019 Jul.
Article em En | MEDLINE | ID: mdl-30951937
ABSTRACT
Arsenic (As) contamination of drinking water is a major cause of As toxicity in many parts of the world. A study was conducted to evaluate As removal from water containing 100-700 µg/L of As and As to Fe concentration ratios of 15-11000 using the coprecipitation process with and without As/Fe adsorption onto granular activated carbon (GAC). Fe concentration required to reduce As concentrations in order to achieve the WHO standard level of 10 µg/L increased exponentially with the increase in initial As concentration. When small amounts of GAC were added to the As/Fe solutions the Fe required to remove these As concentrations reduced drastically. This decline was due to the GAC adsorption of Fe and As, enhancing the removal of these metals through coprecipitation. Predictive regression equations were developed relating the GAC dose requirement to the initial As and Fe concentrations. Zeta potential data revealed that As was adsorbed on the GAC by outer-sphere complexation whereas Fe was adsorbed by inner-sphere complexation reversing the negative charge on GAC to positive values. X-ray diffraction of the GAC samples in the presence of Fe had an additional peak characteristic of ferrihydrite (Fe oxide) compared to that of the GAC sample without Fe. The study showed that incorporating an adsorbent into the coprecipitation process has the advantage of removing As from waters at all concentrations of Fe and As compared to coprecipitation alone which does not remove As to the required levels if Fe concentration is low.