Your browser doesn't support javascript.
loading
Smartwatch for the analysis of rest tremor in patients with Parkinson's disease.
López-Blanco, Roberto; Velasco, Miguel A; Méndez-Guerrero, Antonio; Romero, Juan Pablo; Del Castillo, María Dolores; Serrano, J Ignacio; Rocon, Eduardo; Benito-León, Julián.
Afiliação
  • López-Blanco R; Healthcare Research Institute (i+12), Hospital Universitario 12 de Octubre, Madrid, Spain; Neurology Section, Hospital Virgen de la Poveda, Villa del Prado, Madrid, Spain; Medicine Department, Faculty of Medicine, Universidad Complutense Madrid (UCM), Spain. Electronic address: robretolb@gmail.com.
  • Velasco MA; Neural and Cognitive Engineering Group, Centro de Automática y Robótica (CAR), CSIC-UPM, Madrid, Spain.
  • Méndez-Guerrero A; Neurology Department, Hospital Universitario 12 de Octubre, Madrid, Spain.
  • Romero JP; Faculty of Biosanitary Sciences, Francisco de Vitoria University, Pozuelo de Alarcón, Madrid, Spain; Brain Damage Service, Hospital Beata Maria Ana, Madrid, Spain.
  • Del Castillo MD; Neural and Cognitive Engineering Group, Centro de Automática y Robótica (CAR), CSIC-UPM, Madrid, Spain.
  • Serrano JI; Neural and Cognitive Engineering Group, Centro de Automática y Robótica (CAR), CSIC-UPM, Madrid, Spain.
  • Rocon E; Neural and Cognitive Engineering Group, Centro de Automática y Robótica (CAR), CSIC-UPM, Madrid, Spain.
  • Benito-León J; Medicine Department, Faculty of Medicine, Universidad Complutense Madrid (UCM), Spain; Neurology Department, Hospital Universitario 12 de Octubre, Madrid, Spain; Centro de Investigación Biomédica en Red sobre Enfermedades Neurodegenerativas (CIBERNED), Spain.
J Neurol Sci ; 401: 37-42, 2019 Jun 15.
Article em En | MEDLINE | ID: mdl-31005763
Wearable technology used in Parkinson's disease (PD) research has become an increasing focus of interest in this field. Our group assessed the feasibility, clinical correlation, reliability, and acceptance of smartwatches in order to quantify arm resting tremors in PD patients. An Android application on a smartwatch was used to obtain raw data from the smartwatch's gyroscopes. Twenty-two PD patients were consecutively recruited and followed for 1 year. Arm rest tremors were video filmed and scored by two independent raters using the motor subscale of the Unified Parkinson's Disease Rating Scale (UPDRS-III). The tremor intensity parameter was defined by the root mean square of the angular speed measured by the smartwatch at the wrist. Sixty-four smartwatch evaluations were completed. The Spearman coefficient among the mean of the resting tremor (UPDRS-III) scores and smartwatch measurements for tremor intensity was 0.81 (p < .001); smartwatch reliability to quantify tremors was checked by intraclass reliability coefficient with a resting tremor = 0.89, minimum detectable change = 59.03%. Good acceptance of the system was shown. Smartwatch use for PD tremor analysis is possible, reliable, well-correlated with clinical scores, and well-accepted by patients for clinical follow-up. The results from these experiments suggest that this commodity hardware has the potential to quantify PD patients' tremors objectively in a consulting-room.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doença de Parkinson / Tremor / Dispositivos Eletrônicos Vestíveis Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doença de Parkinson / Tremor / Dispositivos Eletrônicos Vestíveis Idioma: En Ano de publicação: 2019 Tipo de documento: Article