Your browser doesn't support javascript.
loading
Use of fish scales in environmental monitoring by the application of Laser-Induced Breakdown Spectroscopy (LIBS).
Viana, Lucilene Finoto; Súarez, Yzel Rondon; Cardoso, Claudia Andrea Lima; Lima, Sandro Marcio; Andrade, Luis Humberto da Cunha; Lima-Junior, Sidnei Eduardo.
Afiliação
  • Viana LF; Programa de Pós-Graduação em Recursos Naturais (PGRN), Universidade Estadual de Mato Grosso do Sul (UEMS), Rod. Dourados Itahum km 12, Dourados, MS, CEP: 79804-970, Brazil. Electronic address: lucilenefinoto@hotmail.com.
  • Súarez YR; Programa de Pós-Graduação em Recursos Naturais (PGRN), Universidade Estadual de Mato Grosso do Sul (UEMS), Rod. Dourados Itahum km 12, Dourados, MS, CEP: 79804-970, Brazil.
  • Cardoso CAL; Programa de Pós-Graduação em Recursos Naturais (PGRN), Universidade Estadual de Mato Grosso do Sul (UEMS), Rod. Dourados Itahum km 12, Dourados, MS, CEP: 79804-970, Brazil.
  • Lima SM; Programa de Pós-Graduação em Recursos Naturais (PGRN), Universidade Estadual de Mato Grosso do Sul (UEMS), Rod. Dourados Itahum km 12, Dourados, MS, CEP: 79804-970, Brazil.
  • Andrade LHDC; Programa de Pós-Graduação em Recursos Naturais (PGRN), Universidade Estadual de Mato Grosso do Sul (UEMS), Rod. Dourados Itahum km 12, Dourados, MS, CEP: 79804-970, Brazil.
  • Lima-Junior SE; Programa de Pós-Graduação em Recursos Naturais (PGRN), Universidade Estadual de Mato Grosso do Sul (UEMS), Rod. Dourados Itahum km 12, Dourados, MS, CEP: 79804-970, Brazil.
Chemosphere ; 228: 258-263, 2019 Aug.
Article em En | MEDLINE | ID: mdl-31035163
ABSTRACT
The objective of this study was to evaluate the efficiency of Laser-Induced Breakdown Spectroscopy (LIBS) to detect the presence of bioaccumulated Fe and Pb in scales of Salminus brasiliensis and Prochilodus lineatus, and to compare the results from this technique with those obtained using the conventional atomic absorption spectrometry technique. The study used fish collected in the Amambai River, Upper Paraná River, Brazil. The LIBS technique detected the presence of Fe in S. brasiliensis scales and Fe and Pb in P. lineatus scales on different regions. Using atomic absorption spectrometry, we verified a significant difference in Fe concentration in scales between the species analyzed, with a higher concentration in S. brasiliensis than in P. lineatus (p = 0.0004). Pb was not detected using atomic absorption spectrometry in either species because the concentration of this element was below the limit of detection of this technique. The LIBS technique was efficient in detecting Fe and Pb in scales of the two species analyzed, proving to be a promising tool for environmental monitoring.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrofotometria Atômica / Monitoramento Ambiental / Peixes / Lasers Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrofotometria Atômica / Monitoramento Ambiental / Peixes / Lasers Idioma: En Ano de publicação: 2019 Tipo de documento: Article