Your browser doesn't support javascript.
loading
Evaluation of MALDI-TOF/TOF Mass Spectrometry Approach for Quantitative Determination of Aspartate Residue Isomerization in the Amyloid-ß Peptide.
Pekov, Stanislav I; Ivanov, Daniil G; Bugrova, Anna E; Indeykina, Maria I; Zakharova, Natalia V; Popov, Igor A; Kononikhin, Alexey S; Kozin, Sergey A; Makarov, Alexander A; Nikolaev, Evgeny N.
Afiliação
  • Pekov SI; Moscow Institute of Physics and Technology, Dolgoprudny, Moscow region, Russia.
  • Ivanov DG; V.L. Talrose Institute for Energy Problems of Chemical Physics RAS, Moscow, Russia.
  • Bugrova AE; Moscow Institute of Physics and Technology, Dolgoprudny, Moscow region, Russia.
  • Indeykina MI; Emanuel Institute of Biochemical Physics RAS, Moscow, Russia.
  • Zakharova NV; Emanuel Institute of Biochemical Physics RAS, Moscow, Russia.
  • Popov IA; Moscow Institute of Physics and Technology, Dolgoprudny, Moscow region, Russia.
  • Kononikhin AS; Emanuel Institute of Biochemical Physics RAS, Moscow, Russia.
  • Kozin SA; Moscow Institute of Physics and Technology, Dolgoprudny, Moscow region, Russia.
  • Makarov AA; Emanuel Institute of Biochemical Physics RAS, Moscow, Russia.
  • Nikolaev EN; Moscow Institute of Physics and Technology, Dolgoprudny, Moscow region, Russia. popov.ia@phystech.edu.
J Am Soc Mass Spectrom ; 30(7): 1325-1329, 2019 Jul.
Article em En | MEDLINE | ID: mdl-31073890
ABSTRACT
Immunoprecipitation (IP) combined with MALDI-TOF mass spectrometry is a powerful instrument for peptide and protein identification in biological samples. In this study, the analytical capabilities of MALDI-TOF/TOF mass spectrometry for relative quantitation of isoAsp7 in Aß(1-42) and Aß(1-16) were investigated. The possibility of quantitative determination of isoAsp7 in Aß(1-42) with the detection limit as low as 2 pmol has been demonstrated. The same approach was applied for a shorter peptide Aß(1-16) and resulted in enhanced accuracy (± 3.2%), and lower detection limit (50 fmol). Pilot experiments with artificial cerebrospinal fluid and mouse brain tissue were performed and showed that the proposed IP-MALDI-TOF/TOF approach could be applied for measuring isoAß content in biological fluids and tissues. Additionally, it was shown that 6E10 anti-amyloid antibodies might affect the accuracy of the amyloid-ß quantitation in the presence of the isomerized peptide.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fragmentos de Peptídeos / Peptídeos beta-Amiloides / Ácido Aspártico / Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fragmentos de Peptídeos / Peptídeos beta-Amiloides / Ácido Aspártico / Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz Idioma: En Ano de publicação: 2019 Tipo de documento: Article