Your browser doesn't support javascript.
loading
The accuracy of an injection technique for Flexor hallucis longus tendon sheath: A cadaveric study.
Opdam, K T M; Madirolas, X; Zwiers, R; Terra, M P; Reina, F; van Dijk, C N.
Afiliação
  • Opdam KTM; Department of Orthopedic Surgery, Amsterdam UMC, Amsterdam, The Netherlands; Academic Center for Evidence based Sports medicine (ACES), Amsterdam, The Netherlands; Amsterdam Collaboration for Health and Safety in Sports (ACHSS), Amsterdam, The Netherlands. Electronic address: k.t.opdam@amsterdamumc.
  • Madirolas X; Department of Orthopedic Surgery, Hospital Parc Martí Julià, Santa Caterina, Salt, Girona.
  • Zwiers R; Department of Orthopedic Surgery, Amsterdam UMC, Amsterdam, The Netherlands; Academic Center for Evidence based Sports medicine (ACES), Amsterdam, The Netherlands; Amsterdam Collaboration for Health and Safety in Sports (ACHSS), Amsterdam, The Netherlands.
  • Terra MP; Department of Radiology, Amphia Ziekenhuis, The Netherlands.
  • Reina F; NEOMA Research Group, Department of Medical Sciences, Faculty of Medicine, University of Girona, Spain.
  • van Dijk CN; Department of Orthopedic Surgery, Amsterdam UMC, Amsterdam, The Netherlands; Academic Center for Evidence based Sports medicine (ACES), Amsterdam, The Netherlands; Amsterdam Collaboration for Health and Safety in Sports (ACHSS), Amsterdam, The Netherlands; FIFA Medical Centre of excellence Ripoll-de
Foot Ankle Surg ; 26(3): 334-337, 2020 Apr.
Article em En | MEDLINE | ID: mdl-31122874
BACKGROUND: Corticosteroid injections are used in the conservative treatment of Flexor hallucis longus (FHL) tendinopathy. Studies for imaging guided injection are done, however, the accuracy of blind injection has not yet been studied. PURPOSE: The aim of this study was to determine the accuracy of a blind injection technique into the FHL tendon sheath. HYPOTHESIS: We hypothesize that a blind injections technique into the FHL tendon sheath based on clinical examination has a high accuracy. STUDY DESIGN: Descriptive cadaveric study. METHODS: Ten ankles of human cadavers were blindly injected with radiologic contrast mixed with methylene blue into the FHL tendon sheath. After injection, a CT scan of each ankle was performed to evaluate the location of contrast material. CT scans were reviewed by an experienced musculoskeletal radiologist blinded to the procedure. Anatomic dissection was undertaken to assess the location of the injection fluid. RESULTS: In nine ankles the radiological contrast was injected in the FHL tendon sheath. In one cadaver there was a technical problem and was therefore excluded. CONCLUSION: This study shows that the FHL tendon sheath can be blindly injected based on only clinical examination with high accuracy. LEVEL OF EVIDENCE: Descriptive cadaveric study.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Transferência Tendinosa / Tomografia Computadorizada por Raios X / Tendinopatia / Glucocorticoides Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Transferência Tendinosa / Tomografia Computadorizada por Raios X / Tendinopatia / Glucocorticoides Idioma: En Ano de publicação: 2020 Tipo de documento: Article