Your browser doesn't support javascript.
loading
Selective extraction of aliphatic amines by functionalized mesoporous silica-coated solid phase microextraction Arrow.
Lan, Hangzhen; Zhang, Wenzhong; Smått, Jan-Henrik; Koivula, Risto T; Hartonen, Kari; Riekkola, Marja-Liisa.
Afiliação
  • Lan H; Department of Chemistry, University of Helsinki, P.O. Box 55, 00014, Helsinki, Finland.
  • Zhang W; Institute for Atmospheric and Earth System Research, University of Helsinki, P.O. Box 64, 00014, Helsinki, Finland.
  • Smått JH; Department of Chemistry, University of Helsinki, P.O. Box 55, 00014, Helsinki, Finland.
  • Koivula RT; Laboratory of Physical Chemistry, Åbo Akademi University, Porthansgatan 3-5, 20500, Turku, Finland.
  • Hartonen K; Department of Chemistry, University of Helsinki, P.O. Box 55, 00014, Helsinki, Finland.
  • Riekkola ML; Department of Chemistry, University of Helsinki, P.O. Box 55, 00014, Helsinki, Finland.
Mikrochim Acta ; 186(7): 412, 2019 06 11.
Article em En | MEDLINE | ID: mdl-31187285
Mesoporous silica-coated solid phase microextraction (SPME) Arrow systems were developed for capturing of low-molecular-weight aliphatic amines (LMWAAs) from complicated sample matrices. Specifically, silicas of type MCM-41, SBA-15 and KIT-6 were chosen as substrates to afford size-exclusion selectivity. They possess ordered multidimensional pore-channel structures and mesopore sizes between 3.8 and 8.2 nm. Their surface acidity was enhanced by grafting them with a layer of titanium hydrogenphosphate (-TP). This enhanced the chemical selectivity for basic LMWAAs. The siliceous coatings increased the extraction of ethylamine, diethylamine (DEA) and triethylamine (TEA) by factors of 18.6-102.5, 4.8-10.8 and 2.6-4.0, respectively, when compared to the commercial SPME Arrow with polydimethylsiloxane/divinylbenzene coating. Among them, the MCM-41 and MCM-41-TP coated SPME Arrows demonstrated exceptional selectivity towards LMWAAs that were quantified by gas chromatography-mass spectrometry (GC-MS). The total peak area ratios of LMWAAs/ten competing compounds were 25.4 and 36.3, respectively. The extraction equilibrium was reached within 20-30 min. The MCM-41 and MCM-41-TP derived SPME Arrows gave very similar results (18.4 ± 2.1-376 ± 12 ng g-1 to DEA and TEA) when applied to urban mushroom samples. SPME Arrow with MCM-41 coatings followed by GC-MS was applied also to the analysis of atmospheric air and urine samples resulting in high selectivity due to the size and mesoporous structure of the functionalized silica, and its chemical interactions with the LMWAAs. Graphical abstract Scheme of synthesis of the MCM-41 silicas, and the preparation of solid phase microextraction Arrow coatings. They were employed for selective capturing of aliphatic amines from complex sample matrices, followed by gas chromatography-mass spectrometry.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2019 Tipo de documento: Article