Biophysically motivated efficient estimation of the spatially isotropic R2* component from a single gradient-recalled echo measurement.
Papazoglou, Sebastian; Streubel, Tobias; Ashtarayeh, Mohammad; Pine, Kerrin J; Edwards, Luke J; Brammerloh, Malte; Kirilina, Evgeniya; Morawski, Markus; Jäger, Carsten; Geyer, Stefan; Callaghan, Martina F; Weiskopf, Nikolaus; Mohammadi, Siawoosh.
Afiliação
  • Papazoglou S; Department of Systems Neurosciences, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Streubel T; Department of Systems Neurosciences, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Ashtarayeh M; Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany.
  • Pine KJ; Department of Systems Neurosciences, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Edwards LJ; Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany.
  • Brammerloh M; Department of Systems Neurosciences, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Kirilina E; Department of Systems Neurosciences, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
  • Morawski M; Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany.
  • Jäger C; Neurocomputation and Neuroimaging Unit, Department of Education and Psychology, Freie Universität Berlin, Berlin, Germany.
  • Geyer S; Paul Flechsig Institute of Brain Research, University of Leipzig, Leipzig, Germany.
  • Callaghan MF; Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany.
  • Weiskopf N; Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany.
  • Mohammadi S; Wellcome Centre for Human Neuroimaging, UCL Institute of Neurology, London, United Kingdom.
Magn Reson Med ; 82(5): 1804-1811, 2019 11.
Article em En | MEDLINE | ID: mdl-31293007
ABSTRACT

PURPOSE:

To propose and validate an efficient method, based on a biophysically motivated signal model, for removing the orientation-dependent part of R2* using a single gradient-recalled echo (GRE) measurement.

METHODS:

The proposed method utilized a temporal second-order approximation of the hollow-cylinder-fiber model, in which the parameter describing the linear signal decay corresponded to the orientation-independent part of R2* . The estimated parameters were compared to the classical, mono-exponential decay model for R2* in a sample of an ex vivo human optic chiasm (OC). The OC was measured at 16 distinct orientations relative to the external magnetic field using GRE at 7T. To show that the proposed signal model can remove the orientation dependence of R2* , it was compared to the established phenomenological method for separating R2* into orientation-dependent and -independent parts.

RESULTS:

Using the phenomenological method on the classical signal model, the well-known separation of R2* into orientation-dependent and -independent parts was verified. For the proposed model, no significant orientation dependence in the linear signal decay parameter was observed.

CONCLUSIONS:

Since the proposed second-order model features orientation-dependent and -independent components at distinct temporal orders, it can be used to remove the orientation dependence of R2* using only a single GRE measurement.