Your browser doesn't support javascript.
loading
Motion estimation and correction in cardiac CT angiography images using convolutional neural networks.
Lossau Née Elss, T; Nickisch, H; Wissel, T; Bippus, R; Schmitt, H; Morlock, M; Grass, M.
Afiliação
  • Lossau Née Elss T; Philips Research, Hamburg, Germany; Hamburg University of Technology, Germany.
  • Nickisch H; Philips Research, Hamburg, Germany.
  • Wissel T; Philips Research, Hamburg, Germany.
  • Bippus R; Philips Research, Hamburg, Germany.
  • Schmitt H; Philips Research, Hamburg, Germany.
  • Morlock M; Hamburg University of Technology, Germany.
  • Grass M; Philips Research, Hamburg, Germany.
Comput Med Imaging Graph ; 76: 101640, 2019 09.
Article em En | MEDLINE | ID: mdl-31299452
ABSTRACT
Cardiac motion artifacts frequently reduce the interpretability of coronary computed tomography angiography (CCTA) images and potentially lead to misinterpretations or preclude the diagnosis of coronary artery disease (CAD). In this paper, a novel motion compensation approach dealing with Coronary Motion estimation by Patch Analysis in CT data (CoMPACT) is presented. First, the required data for supervised learning is generated by the Coronary Motion Forward Artifact model for CT data (CoMoFACT) which introduces simulated motion to 19 artifact-free clinical CT cases with step-and-shoot acquisition protocol. Second, convolutional neural networks (CNNs) are trained to estimate underlying 2D motion vectors from 2.5D image patches based on the coronary artifact appearance. In a phantom study with computer-simulated vessels, CNNs predict the motion direction and the motion magnitude with average test accuracies of 13.37°±1.21° and 0.77 ±â€¯0.09 mm, respectively. On clinical data with simulated motion, average test accuracies of 34.85°±2.09° and 1.86 ±â€¯0.11 mm are achieved, whereby the precision of the motion direction prediction increases with the motion magnitude. The trained CNNs are integrated into an iterative motion compensation pipeline which includes distance-weighted motion vector extrapolation. Alternating motion estimation and compensation in twelve clinical cases with real cardiac motion artifacts leads to significantly reduced artifact levels, especially in image data with severe artifacts. In four observer studies, mean artifact levels of 3.08 ±â€¯0.24 without MC and 2.28 ±â€¯0.29 with CoMPACT MC are rated in a five point Likert scale.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Radiográfica Assistida por Computador / Redes Neurais de Computação / Angiografia Coronária / Angiografia por Tomografia Computadorizada Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Radiográfica Assistida por Computador / Redes Neurais de Computação / Angiografia Coronária / Angiografia por Tomografia Computadorizada Idioma: En Ano de publicação: 2019 Tipo de documento: Article