Your browser doesn't support javascript.
loading
AgarFix: Simple and accessible stabilization of challenging single-particle cryo-EM specimens through crosslinking in a matrix of agar.
Adamus, Klaudia; Le, Sarah N; Elmlund, Hans; Boudes, Marion; Elmlund, Dominika.
Afiliação
  • Adamus K; Department of Biochemistry and Molecular Biology, Biomedicine Discovery Institute, Monash University, Clayton, VIC 3800, Australia; Australian Research Council Centre of Excellence in Advanced Molecular Imaging, Monash University, Clayton, VIC 3800, Australia.
  • Le SN; Department of Biochemistry and Molecular Biology, Biomedicine Discovery Institute, Monash University, Clayton, VIC 3800, Australia; Australian Research Council Centre of Excellence in Advanced Molecular Imaging, Monash University, Clayton, VIC 3800, Australia.
  • Elmlund H; Department of Biochemistry and Molecular Biology, Biomedicine Discovery Institute, Monash University, Clayton, VIC 3800, Australia; Australian Research Council Centre of Excellence in Advanced Molecular Imaging, Monash University, Clayton, VIC 3800, Australia.
  • Boudes M; Department of Biochemistry and Molecular Biology, Biomedicine Discovery Institute, Monash University, Clayton, VIC 3800, Australia; Australian Research Council Centre of Excellence in Advanced Molecular Imaging, Monash University, Clayton, VIC 3800, Australia. Electronic address: marion.boudes@monas
  • Elmlund D; Department of Biochemistry and Molecular Biology, Biomedicine Discovery Institute, Monash University, Clayton, VIC 3800, Australia; Australian Research Council Centre of Excellence in Advanced Molecular Imaging, Monash University, Clayton, VIC 3800, Australia. Electronic address: dominika.elmlund@mo
J Struct Biol ; 207(3): 327-331, 2019 09 01.
Article em En | MEDLINE | ID: mdl-31323306
Cryogenic electron microscopy (cryo-EM) allows structure determination of macromolecular assemblies that have resisted other structural biology approaches because of their size and heterogeneity. These challenging multi-protein targets are typically susceptible to dissociation and/or denaturation upon cryo-EM grid preparation, and often require crosslinking prior to freezing. Several approaches for gentle on-column or in-tube crosslinking have been developed. On-column crosslinking is not widely applicable because of the poor separation properties of gel filtration techniques. In-tube crosslinking frequently causes sample aggregation and/or precipitation. Gradient-based crosslinking through the GraFix method is more robust, but very time-consuming and necessitates specialised expensive equipment. Furthermore, removal of the glycerol typically involves significant sample loss and may cause destabilization detrimental to the sample quality. Here, we introduce an alternative procedure: AgarFix (Agarose Fixation). The sample is embedded in an agarose matrix that keeps the molecules separated, thus preventing formation of aggregates upon cross-inking. Gentle crosslinking is accomplished by diffusion of the cross-linker into the agarose drop. The sample is recovered by diffusion or electroelution and can readily be used for cryo-EM specimen preparation. AgarFix requires minimal equipment and basic lab experience, making it widely accessible to the cryo-EM community.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Sefarose / Manejo de Espécimes / Microscopia Crioeletrônica / Imagem Individual de Molécula Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Sefarose / Manejo de Espécimes / Microscopia Crioeletrônica / Imagem Individual de Molécula Idioma: En Ano de publicação: 2019 Tipo de documento: Article