Your browser doesn't support javascript.
loading
A cerium vanadate interconnected with a carbon nanofiber heterostructure for electrochemical determination of the prostate cancer drug nilutamide.
Kokulnathan, Thangavelu; Karthik, Raj; Chen, Shen-Ming; Kumar, Jeyaraj Vinoth; Sakthinathan, Subramanian.
Afiliação
  • Kokulnathan T; Electroanalysis and Bioelectrochemistry Laboratory, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No.1, Section 3, Chung-Hsiao East Road, Taipei, 106, Taiwan, Republic of China.
  • Karthik R; Department of Electro-Optical Engineering, National Taipei University of Technology, Taipei, 10608, Taiwan, Republic of China.
  • Chen SM; Electroanalysis and Bioelectrochemistry Laboratory, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No.1, Section 3, Chung-Hsiao East Road, Taipei, 106, Taiwan, Republic of China.
  • Kumar JV; Electroanalysis and Bioelectrochemistry Laboratory, Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No.1, Section 3, Chung-Hsiao East Road, Taipei, 106, Taiwan, Republic of China. smchen78@ms15.hinet.net.
  • Sakthinathan S; Department of Chemistry, Nanomaterials Laboratory, International Research Center, Kalasalingam Academy of Research and Education, Krishnankoil, Tamil Nadu, 626 126, India.
Mikrochim Acta ; 186(8): 579, 2019 07 27.
Article em En | MEDLINE | ID: mdl-31352538
ABSTRACT
Cerium vanadate resembling the shape of a hedgehog were interconnected with carbon nanofibers to give a heterostructure (referred to as CeV/CNF) that exhibits efficient catalytic activity for the electrochemical detection of the drug nilutamide (NLT). The heterostructure material and its modification were characterized by XRD, Raman spectra, XPS, FESEM, TEM, SAED, and EDX. A glassy carbon electrode was modified with the CeV/CNF nanocomposite. Best operated at -0.52 V (vs. Ag/AgCl), it exhibits a very low detection limit (2.0 nM), wide linear range (0.01-540 µM), high sensitivity (1.36 µA µM-1 cm-2) and rapid response towards NLT. It was applied to the determination of NLT in spiked human urine. Graphical abstractSchematic presentation of cerium vanadate interconnected with carbon nanofiber heterostructure for electrochemical determination of prostate cancer drug nilutamide in biological samples.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Vanadatos / Imidazolidinas / Técnicas Eletroquímicas / Nanofibras / Antineoplásicos Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Vanadatos / Imidazolidinas / Técnicas Eletroquímicas / Nanofibras / Antineoplásicos Idioma: En Ano de publicação: 2019 Tipo de documento: Article