Determining a reliably visible and inexpensive surface fiducial marker for use in MRI: a research study in a busy Australian Radiology Department.
Izatt, Maree T; Lees, Deborah; Mills, Susan; Grant, Caroline A; Little, J Paige.
Afiliação
  • Izatt MT; Biomechanics and Spine Research Group, Queensland University of Technology, Brisbane, Queensland, Australia.
  • Lees D; Biomechanics and Spine Research Group, Queensland University of Technology, Brisbane, Queensland, Australia.
  • Mills S; Mater Medical Imaging, Mater Misericordiae Brisbane Ltd, South Brisbane, Queensland, Australia.
  • Grant CA; Biomechanics and Spine Research Group, Queensland University of Technology, Brisbane, Queensland, Australia.
  • Little JP; Biomechanics and Spine Research Group, Queensland University of Technology, Brisbane, Queensland, Australia.
BMJ Open ; 9(8): e027020, 2019 08 01.
Article em En | MEDLINE | ID: mdl-31375607
OBJECTIVES: Single-use commercial surface fiducial markers are used in clinical imaging for a variety of applications. The current study sought to find a new, reliably visible, easily sourced and inexpensive fiducial marker alternative for use with MRI. DESIGN: Five commonly requested MRI sequences were determined (three-dimensional (3D) T1-weighted, T1 coronal, 3D T2-weighted, T2 fat suppressed, proton density), to examine the visibility of 18 items (including a commercial fiducial marker). SETTING: Clinical 3T MRI scanner in an Australian Tertiary Hospital and an Australian University Biomedical Engineering research group. INTERVENTIONS: 18 marker alternatives were scanned using five common MRI sequences. Images were reformatted to obtain both an image through the mid-height of each marker and a maximum intensity z-projection image over the volume of the marker. Variations in marker intensity were profiled across each visible marker and a visibility rating defined. MAIN OUTCOME MEASURES: Outcome measures were based on quantitative assessment of a clear intensity contrast ratio between the marker and the adjacent tissue and a qualitative assessment of visibility via a 3-point scale. RESULTS: The fish oil capsule, vitamin D capsule, paint ball pellet, soy sauce sushi tube and commercial markers were typically visible to a high quality on all the imaging sequences and demonstrated a clear differential in intensity contrast against the adjacent tissue. Other common items, such as plasticine 'play doh' and a soft 'Jelly baby' sweet, were surprise candidates, demonstrating high-quality visibility and intensity contrast for the 3D T1-weighted sequence. CONCLUSIONS: Depending on the basis for referral and MRI sequence chosen, four alternative fiducial markers were determined to be inexpensive, easily sourced and consistently visible. Of these, the vitamin D capsule provided an excellent balance between availability, size, cost, usability and quality of the visualised marker for all the commonly used MRI sequences analysed.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Marcadores Fiduciais Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Marcadores Fiduciais Idioma: En Ano de publicação: 2019 Tipo de documento: Article