Your browser doesn't support javascript.
loading
Differences in left ventricular measurements: Attenuation versus contour based methods.
Liu, Yici; Bourgeois, Sophia; Yam, Yeung; Small, Gary R; Chow, Benjamin J W.
Afiliação
  • Liu Y; Department of Medicine (Cardiology), University of Ottawa Heart Institute, 40 Ruskin St, Ottawa, ON, K1Y 4W7, Canada.
  • Bourgeois S; Department of Medicine (Cardiology), University of Ottawa Heart Institute, 40 Ruskin St, Ottawa, ON, K1Y 4W7, Canada.
  • Yam Y; Department of Medicine (Cardiology), University of Ottawa Heart Institute, 40 Ruskin St, Ottawa, ON, K1Y 4W7, Canada.
  • Small GR; Department of Medicine (Cardiology), University of Ottawa Heart Institute, 40 Ruskin St, Ottawa, ON, K1Y 4W7, Canada.
  • Chow BJW; Department of Medicine (Cardiology), University of Ottawa Heart Institute, 40 Ruskin St, Ottawa, ON, K1Y 4W7, Canada; Department of Radiology, University of Ottawa Faculty of Medicine, 451 Smyth Rd, Ottawa, ON, K1H 8M5, Canada. Electronic address: bchow@ottawaheart.ca.
J Cardiovasc Comput Tomogr ; 13(4): 174-178, 2019.
Article em En | MEDLINE | ID: mdl-31402230
ABSTRACT

BACKGROUND:

Coronary computed tomography angiography (CCTA) left ventricle (LV) volumes have prognostic value. LV measurements however can differ depending on post-processing software. Two common methods are the contour (CON) or attenuation (ATT) based methods. This study aims to determine differences in LV volume measurements using the 2 methods.

METHODS:

LV mid-diastolic volumes (LVMDV) were measured using both ATT and CON from 2 vendors in 750 consecutive patients undergoing CCTA. 500 were measured in a derivation cohort to establish a linear regression equation that would correct for any detected differences between the two methods. The equation was then assessed in 250 cases in the validation cohort. Comparisons were made between intra-vendor LVMDVCON and LVMDVATT as well as inter-vendor LVMDVATT.

RESULTS:

In the derivation cohort, the correlation between the two methods and vendors were very good (0.98 and 0.97 respectively). LVMDVCON was 20.4 ±â€¯7.4% greater than LVMDVATT. LVMDVATT was 9.2 ±â€¯6.6% greater with one vendor compared to the other. Validation cohort corrected LVMDVATT was not statistically different to measured LVMDVATT (p = 0.45).

CONCLUSION:

A systematic difference was found between ATT and CON measuring methods. Using a derived linear regression equation, we were able to correct for differences in measurement techniques. The method of LVMDV measurement requires careful consideration when establishing reference values and extrapolating published study results.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Radiográfica Assistida por Computador / Angiografia Coronária / Angiografia por Tomografia Computadorizada / Ventrículos do Coração Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Radiográfica Assistida por Computador / Angiografia Coronária / Angiografia por Tomografia Computadorizada / Ventrículos do Coração Idioma: En Ano de publicação: 2019 Tipo de documento: Article