Your browser doesn't support javascript.
loading
Composites of Bimetallic Platinum-Cobalt Alloy Nanoparticles and Reduced Graphene Oxide for Electrochemical Determination of Ascorbic Acid, Dopamine, and Uric Acid.
Demirkan, Buse; Bozkurt, Sait; Savk, Aysun; Cellat, Kemal; Gülbagca, Fulya; Nas, Mehmet Salih; Alma, Mehmet Hakki; Sen, Fatih.
Afiliação
  • Demirkan B; Sen Research Group, Department of Biochemistry, Faculty of Arts and Science, Dumlupinar University, Evliya Çelebi Campus, 43100, Kütahya, Turkey.
  • Bozkurt S; Sen Research Group, Department of Biochemistry, Faculty of Arts and Science, Dumlupinar University, Evliya Çelebi Campus, 43100, Kütahya, Turkey.
  • Savk A; Sen Research Group, Department of Biochemistry, Faculty of Arts and Science, Dumlupinar University, Evliya Çelebi Campus, 43100, Kütahya, Turkey.
  • Cellat K; Sen Research Group, Department of Biochemistry, Faculty of Arts and Science, Dumlupinar University, Evliya Çelebi Campus, 43100, Kütahya, Turkey.
  • Gülbagca F; Sen Research Group, Department of Biochemistry, Faculty of Arts and Science, Dumlupinar University, Evliya Çelebi Campus, 43100, Kütahya, Turkey.
  • Nas MS; Sen Research Group, Department of Biochemistry, Faculty of Arts and Science, Dumlupinar University, Evliya Çelebi Campus, 43100, Kütahya, Turkey. mehmet.salih.nas@igdir.edu.tr.
  • Alma MH; Department of Environmental Engineering, Faculty of Engineering, University of Igdir, Igdir, Turkey. mehmet.salih.nas@igdir.edu.tr.
  • Sen F; Department of Environmental Engineering, Faculty of Engineering, University of Igdir, Igdir, Turkey.
Sci Rep ; 9(1): 12258, 2019 08 22.
Article em En | MEDLINE | ID: mdl-31439896
ABSTRACT
The ultimate aim of this study is to produce a composite of bimetallic platinum-cobalt nanoparticles and reduced graphene oxide (Pt-Co@rGO) based biosensor for the detection of ascorbic acid (AA), dopamine (DA) and uric acid (UA). Those are biologically important molecules with the key functions for the human body. Pt-Co@rGO was synthesized using a microwave-assisted technique and utilized for the production of a highly sensitive and stable electrochemical biosensor. Detailed spectral XPS and Raman analysis, XRD, and TEM/HR-TEM characterization were also studied. Due to the superior activity and excellent conductivity of rGO, well-separated oxidation peaks of these biomolecules is proven by DPV (differential pulse voltammetry) and CV (cyclic voltammetry) measurements. The prepared Pt-Co@rGO-based biosensor showed high electrochemical activity, a broad linear response, high sensitivity, and acceptable limit of detection values for individual and simultaneous determination of AA, DA, and UA, under optimized conditions. The linear range of Pt-Co@rGO was found to be 170-200; 35-1500 and 5-800 µM for AA, DA, and UA, respectively. Moreover, the detection limit of the prepared composite was calculated as 0.345; 0.051; 0.172 µM for AA, DA, and UA, respectively. In the field of electrochemical biosensors, Pt-Co@rGO based sensor is highly promising due to its superior sensitivity and good selectivity properties.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Platina / Ácido Ascórbico / Ácido Úrico / Dopamina / Cobalto / Ligas / Técnicas Eletroquímicas / Grafite Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Platina / Ácido Ascórbico / Ácido Úrico / Dopamina / Cobalto / Ligas / Técnicas Eletroquímicas / Grafite Idioma: En Ano de publicação: 2019 Tipo de documento: Article