Your browser doesn't support javascript.
loading
Top-Ten Tips for Dual-Energy CT in MSK Radiology.
Walstra, Frances E; Hickle, Jonathan; Duggan, Peter; Alsharhan, Rashid; Murray, Nicolas; Mallinson, Paul; Munk, Peter; Ouellette, Hugue.
Afiliação
  • Walstra FE; Department of Radiology, Vancouver General Hospital/ University of British Columbia, Vancouver, British Columbia, Canada.
  • Hickle J; Department of Radiology, Vancouver General Hospital/ University of British Columbia, Vancouver, British Columbia, Canada.
  • Duggan P; Department of Radiology, Vancouver General Hospital/ University of British Columbia, Vancouver, British Columbia, Canada.
  • Alsharhan R; Department of Radiology, Vancouver General Hospital/ University of British Columbia, Vancouver, British Columbia, Canada.
  • Murray N; Department of Radiology, Vancouver General Hospital/ University of British Columbia, Vancouver, British Columbia, Canada.
  • Mallinson P; Department of Radiology, Vancouver General Hospital/ University of British Columbia, Vancouver, British Columbia, Canada.
  • Munk P; Department of Radiology, Vancouver General Hospital/ University of British Columbia, Vancouver, British Columbia, Canada.
  • Ouellette H; Department of Radiology, Vancouver General Hospital/ University of British Columbia, Vancouver, British Columbia, Canada.
Semin Musculoskelet Radiol ; 23(4): 392-404, 2019 Aug.
Article em En | MEDLINE | ID: mdl-31509867
ABSTRACT
Dual-energy computed tomography (DECT) has the potential to detect musculoskeletal pathology with greater sensitivity than conventional CT alone at no additional radiation dose to the patient. It therefore has the potential to reduce the need for further diagnostic imaging or procedures (e.g., joint aspirations in the case of gout or magnetic resonance imaging to confirm undisplaced fractures).DECT is a well-established technique for the detection of gout arthropathy. Multiple newer applications have shown clinical potential including bone marrow edema detection and metal artifact reduction. Collagen analysis, bone marrow lesion detection, and iodine mapping in CT arthrography are areas of possible future application and development.This article outlines 10 tips on the use of DECT imaging of the musculoskeletal system, explaining the technique and indications with practical suggestions to help guide the radiologist.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Imagem Radiográfica a Partir de Emissão de Duplo Fóton / Doenças Musculoesqueléticas Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Imagem Radiográfica a Partir de Emissão de Duplo Fóton / Doenças Musculoesqueléticas Idioma: En Ano de publicação: 2019 Tipo de documento: Article