Your browser doesn't support javascript.
loading
Ambulatory Assessment of the Dynamic Margin of Stability Using an Inertial Sensor Network.
Guaitolini, Michelangelo; Aprigliano, Federica; Mannini, Andrea; Micera, Silvestro; Monaco, Vito; Sabatini, Angelo Maria.
Afiliação
  • Guaitolini M; The BioRobotics Institute, Scuola Superiore Sant'Anna, 56127 Pisa, Italy. michelangelo.guaitolini@santannapisa.it.
  • Aprigliano F; Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, 56127 Pisa, Italy. michelangelo.guaitolini@santannapisa.it.
  • Mannini A; The BioRobotics Institute, Scuola Superiore Sant'Anna, 56127 Pisa, Italy. federica.aprigliano@santannapisa.it.
  • Micera S; Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, 56127 Pisa, Italy. federica.aprigliano@santannapisa.it.
  • Monaco V; The BioRobotics Institute, Scuola Superiore Sant'Anna, 56127 Pisa, Italy. andrea.mannini@santannapisa.it.
  • Sabatini AM; Department of Excellence in Robotics & AI, Scuola Superiore Sant'Anna, 56127 Pisa, Italy. andrea.mannini@santannapisa.it.
Sensors (Basel) ; 19(19)2019 Sep 23.
Article em En | MEDLINE | ID: mdl-31547624
ABSTRACT
Loss of stability is a precursor to falling and therefore represents a leading cause of injury, especially in fragile people. Thus, dynamic stability during activities of daily living (ADLs) needs to be considered to assess balance control and fall risk. The dynamic margin of stability (MOS) is often used as an indicator of how the body center of mass is located and moves relative to the base of support. In this work, we propose a magneto-inertial measurement unit (MIMU)-based method to assess the MOS of a gait. Six young healthy subjects were asked to walk on a treadmill at different velocities while wearing MIMUs on their lower limbs and pelvis. We then assessed the MOS by computing the lower body displacement with respect to the leading inverse kinematics approach. The results were compared with those obtained using a camera-based system in terms of root mean square deviation (RMSD) and correlation coefficient (ρ). We obtained a RMSD of ≤1.80 cm and ρ ≥ 0.85 for each walking velocity. The findings revealed that our method is comparable to camera-based systems in terms of accuracy, suggesting that it may represent a strategy to assess stability during ADLs in unstructured environments.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2019 Tipo de documento: Article