Your browser doesn't support javascript.
loading
Patient specific characterization of artery and plaque material properties in peripheral artery disease.
Noble, Christopher; Carlson, Kent D; Neumann, Erica; Dragomir-Daescu, Dan; Erdemir, Ahmet; Lerman, Amir; Young, Melissa.
Afiliação
  • Noble C; Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA.
  • Carlson KD; Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA.
  • Neumann E; Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA.
  • Dragomir-Daescu D; Department of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, MN, USA.
  • Erdemir A; Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA.
  • Lerman A; Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA.
  • Young M; Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, USA. Electronic address: young.melissa@mayo.edu.
J Mech Behav Biomed Mater ; 101: 103453, 2020 01.
Article em En | MEDLINE | ID: mdl-31585351
Patient-specific finite element (FE) modeling of atherosclerotic plaque is challenging, as there is limited information available clinically to characterize plaque components. This study proposes that for the limited data available in vivo, material properties of plaque and artery can be identified using inverse FE analysis and either a simple neo-Hookean constitutive model or assuming linear elasticity provides sufficient accuracy to capture the changes in vessel deformation, which is the available clinical metric. To test this, 10 human cadaveric femoral arteries were each pressurized ex vivo at 6 pressure levels, while intravascular ultrasound (IVUS) and virtual histology (VH) imaging were performed during controlled pull-back to determine vessel geometry and plaque structure. The VH images were then utilized to construct FE models with heterogeneous material properties corresponding to the vessel plaque components. The constitutive models were then fit to each plaque component by minimizing the difference between the experimental and the simulated geometry using the inverse FE method. Additionally, we further simplified the analysis by assuming the vessel wall had a homogeneous structure, i.e. lumping artery and plaque as one tissue. We found that for the heterogeneous wall structure, the simulated and experimental vessel geometries compared well when the fitted neo-Hookean parameters or elastic modulus, in the case of linear elasticity, were utilized. Furthermore, taking the median of these fitted parameters then inputting these as plaque component mechanical properties in the finite element simulation yielded differences between simulated and experimental geometries that were on average around 2% greater (1.30-5.55% error range to 2.33-11.71% error range). For the homogeneous wall structure the simulated and experimental wall geometries had an average difference of around 4% although when the difference was calculated using the median fitted value this difference was larger than for the heterogeneous fits. Finally, comparison to uniaxial tension data and to literature constitutive models also gave confidence to the suitability of this simplified approach for patient-specific arterial simulation based on data that may be acquired in the clinic.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Análise de Elementos Finitos / Artéria Femoral / Doença Arterial Periférica / Modelagem Computacional Específica para o Paciente Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Análise de Elementos Finitos / Artéria Femoral / Doença Arterial Periférica / Modelagem Computacional Específica para o Paciente Idioma: En Ano de publicação: 2020 Tipo de documento: Article