A multichannel system integrating molecularly imprinted conductive polymers for ultrasensitive voltammetric determination of four steroid hormones in urine.
Lee, Mei-Hwa; Thomas, James L; Liu, Wei-Chiun; Zhang, Zheng-Xiang; Liu, Bin-Da; Yang, Chien-Hsin; Lin, Hung-Yin.
Afiliação
  • Lee MH; Department of Materials Science and Engineering, I-Shou University, Kaohsiung, 84001, Taiwan.
  • Thomas JL; Department of Physics and Astronomy, University of New Mexico, Albuquerque, NM, 87131, USA.
  • Liu WC; Department of Electrical Engineering, National Cheng Kung University, Tainan, 701, Taiwan.
  • Zhang ZX; Department of Chemical and Materials Engineering, National University of Kaohsiung (NUK), 700, Kaohsiung University Rd., Nan-Tzu District, Kaohsiung, 81148, Taiwan.
  • Liu BD; Department of Electrical Engineering, National Cheng Kung University, Tainan, 701, Taiwan.
  • Yang CH; Department of Chemical and Materials Engineering, National University of Kaohsiung (NUK), 700, Kaohsiung University Rd., Nan-Tzu District, Kaohsiung, 81148, Taiwan. yangch@nuk.edu.tw.
  • Lin HY; Department of Chemical and Materials Engineering, National University of Kaohsiung (NUK), 700, Kaohsiung University Rd., Nan-Tzu District, Kaohsiung, 81148, Taiwan. linhy@ntu.edu.tw.
Mikrochim Acta ; 186(11): 695, 2019 10 14.
Article em En | MEDLINE | ID: mdl-31612312
ABSTRACT
This work reports on a modularized electrochemical method for the determination of the hormones cortisol, progesterone, testosterone and 17ß-estradiol in urine. These hormones were employed as templates when generating molecular imprints from aniline and metanilic acid by electropolymerization on the surface of screen-printed electrodes. The electrically conductive imprint was characterized by SEM, AFM and cyclic voltammetry. A four-channel system was then established to enable simultaneous determination of the hormones by cyclic voltammetry. The detection limits for cortisol, progesterone, testosterone and 17ß-estradiol are as low as 2, 2.5, 10 and 9 ag·mL-1 (for S/N = 3). Graphical abstract A four-channel system was established to enable simultaneous determination of 4 steroid hormones by cyclic voltammetry and by using moleculalry imprinted polymers.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Polímeros / Progesterona / Testosterona / Hidrocortisona / Estradiol / Técnicas Eletroquímicas Idioma: En Ano de publicação: 2019 Tipo de documento: Article