Your browser doesn't support javascript.
loading
Evaluation of the marginal fit of metal copings fabricated by using 3 different CAD-CAM techniques: Milling, stereolithography, and 3D wax printer.
Khaledi, Amir-Alireza; Farzin, Mitra; Akhlaghian, Marzieh; Pardis, Soheil; Mir, Negar.
Afiliação
  • Khaledi AA; Assistant Professor, Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.
  • Farzin M; Associate Professor, Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.
  • Akhlaghian M; Postgraduate student, Department of Prosthodontics, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.
  • Pardis S; Assistant Professor, Department of Oral Pathology, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.
  • Mir N; Assistant Professor, Department of Prosthodontics, School of Dentistry, Zahedan University of Medical Sciences, Zahedan, Iran. Electronic address: negarmir0036@gmail.com.
J Prosthet Dent ; 124(1): 81-86, 2020 Jul.
Article em En | MEDLINE | ID: mdl-31672421
ABSTRACT
STATEMENT OF

PROBLEM:

Digital systems have been developed as substitutes for the traditional fabrication of wax patterns and definitive restorations, but the accuracy of these systems is unclear.

PURPOSE:

The purpose of this in vitro study was to evaluate and compare the marginal fit of metal copings fabricated from milling, stereolithography (SLA), and 3D wax printer (PolyJet) patterns. MATERIAL AND

METHODS:

A standard machined brass die model was designed and prepared. To fabricate metal copings of standardized shape and dimensions, the die was scanned and nickel-chromium (Ni-Cr) copings were designed by using a dental designer software program. By using the same CAD data to fabricate 30 patterns through milling, SLA, and PolyJet techniques, 10 resin patterns were milled by using a 5-axis milling machine, 10 resin patterns were produced by using a NextDent 5100 3D Printer, and 10 wax patterns were printed by using a Solidscape 3D printer. The patterns were invested and cast in Ni-Cr alloy. Each coping was evaluated by using a digital microscope on 16 points around the finish line on the metal die at ×230 magnification. The mean marginal discrepancy was calculated. The mean differences among the groups were compared by using 1-way ANOVA, and post hoc analysis was used for pairwise comparison of the groups (α=.05).

RESULTS:

The mean value of marginal discrepancy was 93.1 ±25 µm in the milling, 71.1 ±25 µm in the SLA, and 41.3 ±6 µm in the PolyJet group. No statistically significant difference was found between the milling and SLA groups (P=.158), while the PolyJet group showed significantly lower mean marginal discrepancy than the 2 other groups (P<.05).

CONCLUSIONS:

The PolyJet method produces metal copings with better marginal fit than the SLA or milling techniques. However, the marginal fit was clinically acceptable in metal copings made with all the 3 methods.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Adaptação Marginal Dentária / Estereolitografia Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Adaptação Marginal Dentária / Estereolitografia Idioma: En Ano de publicação: 2020 Tipo de documento: Article