Your browser doesn't support javascript.
loading
Evaluation of RealStar® Alpha Herpesvirus PCR Kit for Detection of HSV-1, HSV-2, and VZV in Clinical Specimens.
Yip, Cyril C Y; Sridhar, Siddharth; Leung, Kit-Hang; Cheng, Andrew K W; Chan, Kwok-Hung; Chan, Jasper F W; Cheng, Vincent C C; Yuen, Kwok-Yung.
Afiliação
  • Yip CCY; Department of Microbiology, Queen Mary Hospital, Hong Kong, China.
  • Sridhar S; Department of Microbiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China.
  • Leung KH; State Key Laboratory of Emerging Infectious Diseases, The University of Hong Kong, Hong Kong, China.
  • Cheng AKW; Research Centre of Infection and Immunology, The University of Hong Kong, Hong Kong, China.
  • Chan KH; Carol Yu Centre for Infection, The University of Hong Kong, Hong Kong, China.
  • Chan JFW; Department of Microbiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China.
  • Cheng VCC; Department of Microbiology, Queen Mary Hospital, Hong Kong, China.
  • Yuen KY; Department of Microbiology, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong, China.
Biomed Res Int ; 2019: 5715180, 2019.
Article em En | MEDLINE | ID: mdl-31687393
Several commercial PCR kits are available for detection of herpes simplex virus (HSV) and varicella zoster virus (VZV), but the test performance of one CE-marked in vitro diagnostic kit-RealStar® alpha Herpesvirus PCR Kit-has not been well studied. This study evaluated the performance of RealStar® alpha Herpesvirus PCR Kit 1.0 on the LightCycler® 480 Instrument II for detection and differentiation of HSV-1, HSV-2, and VZV in human clinical specimens. We evaluated the analytical sensitivity of the RealStar® and in-house multiplex real-time PCR assays using serial dilutions of nucleic acids extracted from clinical specimens. The analytical sensitivity of the RealStar® assay was 10, 32, and 100 copies/reaction for HSV-1, HSV-2, and VZV, respectively, which was slightly higher than that of the in-house multiplex real-time PCR assay. Reproducibility of the cycle threshold (Cp) values for each viral target was satisfactory with the intra- and interassay coefficient of variation values below 5% for both assays. One-hundred and fifty-three clinical specimens and 15 proficiency testing samples were used to evaluate the diagnostic performance of RealStar® alpha Herpesvirus PCR Kit against the in-house multiplex real-time PCR assay. The RealStar® assay showed 100% sensitivity and specificity when compared to the in-house assay. Cp values of the RealStar® and in-house assays showed excellent correlation. RealStar® alpha Herpesvirus PCR is a sensitive, specific, and reliable assay for the detection of HSV-1, HSV-2, and VZV, with less extensive verification requirements compared to a laboratory developed assay.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Herpesvirus Humano 2 / Herpesvirus Humano 1 / Herpesvirus Humano 3 / Reação em Cadeia da Polimerase Multiplex / Reação em Cadeia da Polimerase em Tempo Real Idioma: En Ano de publicação: 2019 Tipo de documento: Article