Your browser doesn't support javascript.
loading
Streptavidin-exposed magnetic nanoparticles for lectin magnetic separation (LMS) of Staphylococcus aureus prior to three quantification strategies.
Yang, Guotai; Huang, Min; Wang, Yutong; Chen, Guanhua; Zhao, Yu; Xu, Hengyi.
Afiliação
  • Yang G; State Key Laboratory of Food Science and Technology, Nanchang University, 235 Nanjing East Road, Nanchang, 330047, People's Republic of China.
  • Huang M; GanSu Second Provincial People's Hospital, Lanzhou, 730000, People's Republic of China.
  • Wang Y; State Key Laboratory of Food Science and Technology, Nanchang University, 235 Nanjing East Road, Nanchang, 330047, People's Republic of China.
  • Chen G; State Key Laboratory of Food Science and Technology, Nanchang University, 235 Nanjing East Road, Nanchang, 330047, People's Republic of China.
  • Zhao Y; State Key Laboratory of Food Science and Technology, Nanchang University, 235 Nanjing East Road, Nanchang, 330047, People's Republic of China.
  • Xu H; State Key Laboratory of Food Science and Technology, Nanchang University, 235 Nanjing East Road, Nanchang, 330047, People's Republic of China. kidyxu@163.com.
Mikrochim Acta ; 186(12): 813, 2019 11 19.
Article em En | MEDLINE | ID: mdl-31745666
ABSTRACT
A lectin magnetic separation (LMS) method for Staphylococcus aureus (S. aureus) was developed with the aim to improve the efficiency of magnetic nanoparticles and to expand the scope of bacterial recognition. Poly(ethylene glycol) (PEG)-mediated magnetic nanoparticles modified with streptavidin (MNP-PEG-SA) were synthesized and then applied to a two-step LMS based on the use of wheat germ agglutinin (WGA). Three specific methods for S. aureus detection (suitable for different requirements including detection time and sensitivity) were designed. The new LMS has improved anchoring efficiency (compared to two-step LMS methods) and requires a reduced number of magnetic particles. The Baird-Parker (B-P) method can detect S. aureus with a detection limit of 3 × 100 CFU·mL-1 within 15 h; the polymerase chain reaction (PCR) method can be finished within 4 h, with the lowest detection limit (LOD) of 3 × 102 CFU·mL-1. The LOD of HRP-pig IgG-based colorimetric method is 3 × 105 CFU·mL-1, and the method only lasts for 2 h. If combined with specific detection methods, it meets different needs for rapid detection of S. aureus. Graphical abstractSchematic representation of lectin magnetic separation (LMS) based on biotin-wheat germ agglutinin (WGA) and poly (ethylene glycol) (PEG)-mediated streptavidin-modified magnetic nanoparticles (MNP-PEG-SA) and three different quantification strategies (including B-P culture assay, PCR assay, and colorimetric assay) for S. aureus.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Staphylococcus aureus / Aglutininas do Germe de Trigo / Estreptavidina / Nanopartículas Idioma: En Ano de publicação: 2019 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Staphylococcus aureus / Aglutininas do Germe de Trigo / Estreptavidina / Nanopartículas Idioma: En Ano de publicação: 2019 Tipo de documento: Article