Application of the descending branch of the lateral circumflex femoral artery in coronary artery bypass grafting.
Luo, Xin-Jin; Wang, Yue-Tang; Wang, Wei; Xu, Dong-Hui; Wang, Xu; Hu, Sheng-Shou.
Afiliação
  • Luo XJ; Department of Cardiovascular Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China. Electronic address: luoxinjin@yahoo.com.
  • Wang YT; Department of Cardiovascular Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Wang W; Department of Cardiovascular Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Xu DH; Department of Cardiovascular Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Wang X; Department of Cardiovascular Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
  • Hu SS; Department of Cardiovascular Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
J Thorac Cardiovasc Surg ; 161(4): 1266-1271, 2021 04.
Article em En | MEDLINE | ID: mdl-31767359
ABSTRACT

OBJECTIVE:

To investigate a technical method for harvesting and using the descending branch of the lateral circumflex femoral artery (DLCFA) in coronary artery bypass grafting (CABG).

METHODS:

Between January 2017 and January 2019, 40 patients (36 in the planed selection group and 4 in the temporary decision group) with mean age of 49.1 ± 7.5 years received DLCFA as an arterial conduit in CABG. In all patients, the DLCFA was successfully harvested via an anterior thigh incision. Depending on the location of the target vessel, the DLCFA was used as a free graft or a composite graft.

RESULTS:

Of the 44 patients in the planned selection group, DLCFA harvesting was abandoned in 8 patients because computed tomographic angiography revealed anatomical variation or stenosis of the superficial femoral artery. Of the 5 patients in the temporary decision group, harvesting was abandoned in 1 because of short length and thin caliber. On an average, 3.7 ± 0.9 distal anastomoses were created during CABG, with no adverse effects. The length of the harvested DLCFA was 9.9 ± 1.7 cm, with an average proximal lumen diameter of 3.4 ± 0.7 mm. The DLCFA was used as a free graft in 26 patients and as a "Y"-shape composite graft in 14 patients. Total arterial CABG was performed in 75% of the patients.

CONCLUSIONS:

The DLCFA is an alternative conduit for CABG. It can be harvested easily and safely. However, preoperative computed tomographic angiography examination is necessary for the smooth application of the DLCFA, and an appropriate strategy for graft establishment should be considered.