Your browser doesn't support javascript.
loading
Wear behaviour of polyethylene glenoid inserts against PyroCarbon humeral heads in shoulder arthroplasties.
Ramírez-Martínez, Israel; Smith, Simon L; Trail, Ian A; Joyce, Thomas J.
Afiliação
  • Ramírez-Martínez I; Bioengineering Group, School of Engineering, Newcastle University, Newcastle upon Tyne, NE1 7RU, England, United Kingdom. Electronic address: i.ramirez-martinez2@newcastle.ac.uk.
  • Smith SL; Bioengineering Group, School of Engineering, Newcastle University, Newcastle upon Tyne, NE1 7RU, England, United Kingdom.
  • Trail IA; Upper Limb Research Department, Wrightington Hospital, Hall Lane, Appley Bridge, Wigan, Lancashire, WN6 9EP, England, United Kingdom.
  • Joyce TJ; Bioengineering Group, School of Engineering, Newcastle University, Newcastle upon Tyne, NE1 7RU, England, United Kingdom. Electronic address: Thomas.Joyce@newcastle.ac.uk.
J Mech Behav Biomed Mater ; 103: 103553, 2020 03.
Article em En | MEDLINE | ID: mdl-31790849
ABSTRACT
The generation of polyethylene wear debris, and the subsequent tissue reaction to such debris is considered to be a limitation in the long-term survival of shoulder arthroplasties. The purpose of this study was to investigate, for the first time, the wear of a novel PyroCarbon-on-Polyethylene (PyCoP) shoulder arthroplasty system. A 5 million cycle wear test was performed on PyroCarbon humeral heads, which were articulated against commercially available polyethylene glenoid insert components to form an anatomic total shoulder arthroplasty (aTSA). A "Repeat-motion-load" physiological combined cycle was applied using the unique Newcastle Shoulder Wear Simulator. Wear was assessed gravimetrically, and the change of the surface roughness was measured with a non-contacting profilometer. The mean wear rate of the ultra-high molecular weight polyethylene (UHMWPE) components was 19.3 ± 9.5 mm3/million cycles after 5 million cycles of testing. The roughness value, Sa, of the UHMWPE glenoid inserts, reduced, changing from 296 ± 28 nm Sa to 32 ± 8 nm Sa. In contrast, the mean roughness of the PyroCarbon humeral heads remained in the same range (21 ± 2 nm Sa to 20 ± 10 nm Sa). There was no reduction in weight (no measurable wear) of the PyroCarbon humeral heads over the duration of testing. This study is the first to describe the wear performance of UHMWPE glenoid inserts against PyroCarbon humeral heads. No significant difference in the wear of UHMWPE was found in comparison with published studies.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Polietileno / Artroplastia do Ombro Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Polietileno / Artroplastia do Ombro Idioma: En Ano de publicação: 2020 Tipo de documento: Article