Your browser doesn't support javascript.
loading
Mass Activated Droplet Sorting (MADS) Enables High-Throughput Screening of Enzymatic Reactions at Nanoliter Scale.
Holland-Moritz, Daniel A; Wismer, Michael K; Mann, Benjamin F; Farasat, Iman; Devine, Paul; Guetschow, Erik D; Mangion, Ian; Welch, Christopher J; Moore, Jeffrey C; Sun, Shuwen; Kennedy, Robert T.
Afiliação
  • Holland-Moritz DA; Dept. of Chemistry, University of Michigan, 930 N University, Ann Abor, MI, 48109, USA.
  • Wismer MK; Scientific Engineering and Design, Merck & Co., Inc., 2000 Galloping Hill Road, Kenilworth, NJ, 07033, USA.
  • Mann BF; Process Research and Development, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, NJ, 07065, USA.
  • Farasat I; Janssen R&D, 1400 McKean Rd., Spring House, PA, 19477, USA.
  • Devine P; Process Research and Development, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, NJ, 07065, USA.
  • Guetschow ED; Process Research and Development, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, NJ, 07065, USA.
  • Mangion I; Process Research and Development, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, NJ, 07065, USA.
  • Welch CJ; Indiana Consortium Analyt Sci & Engn, Indianapolis, IN, 46202, USA.
  • Moore JC; Process Research and Development, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, NJ, 07065, USA.
  • Sun S; Process Research and Development, Merck & Co., Inc., 126 E. Lincoln Ave, Rahway, NJ, 07065, USA.
  • Kennedy RT; Dept. of Chemistry, University of Michigan, 930 N University, Ann Abor, MI, 48109, USA.
Angew Chem Int Ed Engl ; 59(11): 4470-4477, 2020 03 09.
Article em En | MEDLINE | ID: mdl-31868984
ABSTRACT
Microfluidic droplet sorting enables the high-throughput screening and selection of water-in-oil microreactors at speeds and volumes unparalleled by traditional well-plate approaches. Most such systems sort using fluorescent reporters on modified substrates or reactions that are rarely industrially relevant. We describe a microfluidic system for high-throughput sorting of nanoliter droplets based on direct detection using electrospray ionization mass spectrometry (ESI-MS). Droplets are split, one portion is analyzed by ESI-MS, and the second portion is sorted based on the MS result. Throughput of 0.7 samples s-1 is achieved with 98 % accuracy using a self-correcting and adaptive sorting algorithm. We use the system to screen ≈15 000 samples in 6 h and demonstrate its utility by sorting 25 nL droplets containing transaminase expressed in vitro. Label-free ESI-MS droplet screening expands the toolbox for droplet detection and recovery, improving the applicability of droplet sorting to protein engineering, drug discovery, and diagnostic workflows.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Piridinas / Microfluídica / Ensaios Enzimáticos / Ensaios de Triagem em Larga Escala / Aminas / Transaminases Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Piridinas / Microfluídica / Ensaios Enzimáticos / Ensaios de Triagem em Larga Escala / Aminas / Transaminases Idioma: En Ano de publicação: 2020 Tipo de documento: Article