Your browser doesn't support javascript.
loading
Neutronic study of the 2-MW TRIGA MARK-II research reactor by the deterministic codes DRAGON5 & DONJON5.
El Yaakoubi, H; Boukhal, H; El Bardouni, T; Chakir, E; El Hajjaji, O; Chham, E; El Bakkari, B; Boulaich, Y; Azougagh, M.
Afiliação
  • El Yaakoubi H; ERSN, Faculty of Sciences, Abdelmalek Essaadi University, Tetouan, Morocco. Electronic address: elyaakoubi.houda-etu@uae.ac.ma.
  • Boukhal H; ERSN, Faculty of Sciences, Abdelmalek Essaadi University, Tetouan, Morocco.
  • El Bardouni T; ERSN, Faculty of Sciences, Abdelmalek Essaadi University, Tetouan, Morocco.
  • Chakir E; SimoLab, Faculty of Sciences, University Ibn Tofail Kenitra, Morocco.
  • El Hajjaji O; ERSN, Faculty of Sciences, Abdelmalek Essaadi University, Tetouan, Morocco.
  • Chham E; ERSN, Faculty of Sciences, Abdelmalek Essaadi University, Tetouan, Morocco.
  • El Bakkari B; CNESTEN, National Centre of Sciences, Energy and Nuclear Techniques, Reactor Operating Unit, Rabat, Morocco.
  • Boulaich Y; CNESTEN, National Centre of Sciences, Energy and Nuclear Techniques, Reactor Operating Unit, Rabat, Morocco.
  • Azougagh M; ENSET, Mohamed V University, Rabat, Morocco.
Appl Radiat Isot ; 157: 109026, 2020 Mar.
Article em En | MEDLINE | ID: mdl-31889682
The main objective of this work is to perform a neutronic study of the 2 MW TRIGA MARK-II research reactor of the National Centre of Sciences, Energy and Nuclear Techniques (CNESTEN), Rabat, Morocco and then validate the results by comparing the experimental values and those published for an ordinary 2 MW TRIGA MARK II research reactor. The core diffusion code DONJON5 and the lattice code DRAGON5 were coupled to perform a full model of the TRIGA core and their consistency and accuracy were established by benchmarking the TRIGA experiments. In this study, the nuclear data libraries ENDF/B-VII.1 and JEFF3.1 based on 172 energy groups were used. The group constants of all the reactor components were generated using DRAGON5 code and the collision probability method. These group constants were used then in the DONJON5 core code to calculate the multiplication factor, core excess reactivity, total and integral control rods worth as well as power peaking factors. Good agreement found between the calculated and measured results.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2020 Tipo de documento: Article