Your browser doesn't support javascript.
loading
Controlling the mixed potential of polyelectrolyte-coated platinum electrodes for the potentiometric detection of hydrogen peroxide.
Baez, Jhonattan F; Compton, Matthew; Chahrati, Sylviane; Cánovas, Rocío; Blondeau, Pascal; Andrade, Francisco J.
Afiliação
  • Baez JF; Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira I Virgili (URV), Campus Sescelades, C/. Marcel·lí Domingo 1, Tarragona, 43007, Spain.
  • Compton M; Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira I Virgili (URV), Campus Sescelades, C/. Marcel·lí Domingo 1, Tarragona, 43007, Spain.
  • Chahrati S; Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira I Virgili (URV), Campus Sescelades, C/. Marcel·lí Domingo 1, Tarragona, 43007, Spain.
  • Cánovas R; Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira I Virgili (URV), Campus Sescelades, C/. Marcel·lí Domingo 1, Tarragona, 43007, Spain.
  • Blondeau P; Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira I Virgili (URV), Campus Sescelades, C/. Marcel·lí Domingo 1, Tarragona, 43007, Spain.
  • Andrade FJ; Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira I Virgili (URV), Campus Sescelades, C/. Marcel·lí Domingo 1, Tarragona, 43007, Spain. Electronic address: franciscojavier.andrade@urv.cat.
Anal Chim Acta ; 1097: 204-213, 2020 Feb 08.
Article em En | MEDLINE | ID: mdl-31910961
ABSTRACT
The use of a Pt electrode coated with a layer of Nafion has been described in previous works as an attractive way to perform the potentiometric detection of hydrogen peroxide. Despite of the attractive features of this approach, the nature of the non-Nernstian response of this system was not properly addressed. In this work, using a mixed potential model, the open circuit potential of the Pt electrode is shown to be under kinetic control of the oxygen reduction reaction (ORR). It is proposed that hydrogen peroxide acts as an oxygenated species that blocks free sites on the Pt surface, interfering with the ORR. Therefore, the effect of the polyelectrolyte coating can be understood in terms of the modulation of the factors that affects the kinetics of the ORR, such as an increase of the H+ concentration, minimization of the effect of the spectator species, etc. Because of the complexity and the lack of models that accurately describe systems with practical applications, this work is not intended to provide a mechanistic but rather a phenomenological view on problem. A general framework to understand the factors that affect the potentiometric response is provided. Experimental evidence showing that the use of polyelectrolyte coatings are a powerful way to control the mixed potential open new ways for the development of robust and simple potentiometric sensors.