Your browser doesn't support javascript.
loading
CT-pathologic correlation of non-calcified atherosclerotic arterial plaques: a study using carotid endarterectomy specimens.
Higashi, Masahiro; Yamada, Naoaki; Imakita, Satoshi; Yutani, Chikao; Ishibashi-Ueda, Hatsue; Iihara, Koji; Naito, Hiroaki.
Afiliação
  • Higashi M; Department of Radiology, National Hospital Organization Osaka National Hospital, Osaka, Japan.
  • Yamada N; Department of Radiology, National Cerebral and Cardiovascular Center, Suita, Japan.
  • Imakita S; Department of Radiology, National Cerebral and Cardiovascular Center, Suita, Japan.
  • Yutani C; Hi-Medic Clinic, Osaka, Japan.
  • Ishibashi-Ueda H; Department of Pathology, Amagasaki Central Hospital, Amagasaki, Japan.
  • Iihara K; Department of Pathology, Cardiovascular Center Osaka Gyoumeikan Hospital, Osaka, Japan.
  • Naito H; Department of Pathology, National Cerebral and Cardiovascular Center, Suita, Japan.
Br J Radiol ; 93(1109): 20190901, 2020 May 01.
Article em En | MEDLINE | ID: mdl-31999208
ABSTRACT

OBJECTIVE:

Pathologic features of atherosclerotic plaques on CT are not established. We compared CT values among pathologically confirmed plaque constituents and evaluated their ability to distinguish plaque constituents.

METHODS:

50 histopathological images of carotid endarterectomy samples from 10 males and 2 females (age 54-74 years, average 65.9 years) were examined. We compared pre-operative CT [pre-contrast (CT-P), early post-contrast phase (CT-E), delayed post-contrast phase (CT-D)] of lipid-rich necrotic core (NC) and fibrous tissue (F) plaque components with pathological images. The ability of features to differentiate plaque components using several discrimination techniques were compared.

RESULTS:

CT values of NC and F were 36 ± 13, 45 ± 11 (mean ± standard deviation, Hounsfield unit, HU), 41 ± 17, 69 ± 18, and 44 ± 16, 70 ± 13 in CT-P (p < 0.01), CT-E (p < 0.0001), and CT-D (p < 0.0001), respectively. The threshold, sensitivity, and accuracy for distinguishing NC from F were 44 HU, 74%, and 68%; 55 HU, 85%, and 85%; and 63 HU, 92%, and 84% in CTP, CT-E, and CT-D, respectively. CT-P had lower accuracy than CT-E and CT-D (both p < 0.05), but CT-E and CT-D were similar. CT-E and CT-D yielded 90 and 91% sensitivity and accuracy, respectively in linear discrimination analysis.

CONCLUSION:

In both pre- and post-contrast CT, CT values were lower in NC than F. Although values overlapped, using two-phase post-contrast CTs improved discrimination ability. ADVANCES IN KNOWLEDGE Our findings may help to establish computer-aided diagnosis of vulnerable atherosclerotic plaques in future.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Estenose das Carótidas / Placa Aterosclerótica Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Estenose das Carótidas / Placa Aterosclerótica Idioma: En Ano de publicação: 2020 Tipo de documento: Article