Effects of enhanced depth imaging and en face averaging on optical coherence tomography angiography image quantification.
Liu, Keke; Mehta, Nihaal; Alibhai, A Yasin; Arya, Malvika; Sorour, Osama; Ishibazawa, Akihiro; Byon, Iksoo; Baumal, Caroline R; Witkin, Andre J; Duker, Jay S; Sadda, SriniVas R; Waheed, Nadia K.
Afiliação
  • Liu K; New England Eye Center, Tufts Medical Center, Boston, MA, USA.
  • Mehta N; University of Hawai'i John A. Burns School of Medicine, Honolulu, HI, USA.
  • Alibhai AY; New England Eye Center, Tufts Medical Center, Boston, MA, USA.
  • Arya M; The Warren Alpert Medical School of Brown University, Providence, RI, USA.
  • Sorour O; New England Eye Center, Tufts Medical Center, Boston, MA, USA.
  • Ishibazawa A; New England Eye Center, Tufts Medical Center, Boston, MA, USA.
  • Byon I; New England Eye Center, Tufts Medical Center, Boston, MA, USA.
  • Baumal CR; Department of Ophthalmology, Tanta University, Tanta, Egypt.
  • Witkin AJ; New England Eye Center, Tufts Medical Center, Boston, MA, USA.
  • Duker JS; Department of Ophthalmology, Asahikawa Medical University, Asahikawa, Japan.
  • Sadda SR; Doheny Image Reading Center, Doheny Eye Institute, Los Angeles, CA, USA.
  • Waheed NK; Department of Ophthalmology, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA.
Graefes Arch Clin Exp Ophthalmol ; 258(5): 979-986, 2020 May.
Article em En | MEDLINE | ID: mdl-32020294
PURPOSE: To examine the effects of enhanced depth imaging (EDI) and en face averaging on global vascular measurements of optical coherence tomography angiography (OCTA) images. METHODS: All eyes were imaged with 3 mm × 3 mm fields centered at the fovea using the Carl Zeiss Cirrus 5000 spectral-domain OCTA, with and without EDI, and the Zeiss PLEX Elite 9000 swept-source OCTA. Vessel area density (VAD), vessel length (VL), and vessel diameter index (VDI) were calculated for the superficial capillary plexus (SCP) en face angiograms. For the choriocapillaris (CC), VAD and the number, total area, and average size of flow voids were calculated. These metrics were compared between SD- and SS-OCTA images, with and without en face averaging and EDI. RESULTS: Both averaging and EDI had a significant effect on quantitative metrics. EDI images trended toward a decrease in SCP VAD. In the CC, EDI decreased average flow void size. Averaging increased CC VAD while decreasing number of flow voids, total flow void area, and average flow void size. With both averaging and EDI, SD-OCTA was not able to visualize as many CC flow voids, particularly of a smaller size, compared with SS-OCTA. CONCLUSIONS: Averaging and EDI affect quantitative metrics from SCP and CC OCTA images. EDI resulted in a trend toward decreased VAD in SCP images. Averaging had a major effect on CC imaging. Even with the combination of EDI and en face averaging, SD-OCTA images do not appear to approximate SS-OCTA images in terms of quantitative metrics. This has implications for clinical and research use of SD-OCTA for retinal imaging.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Veias / Angiofluoresceinografia / Corioide / Artérias Ciliares / Tomografia de Coerência Óptica Idioma: En Ano de publicação: 2020 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Veias / Angiofluoresceinografia / Corioide / Artérias Ciliares / Tomografia de Coerência Óptica Idioma: En Ano de publicação: 2020 Tipo de documento: Article