In-Vivo and Ex-Vivo Measurements of Blood Glucose Using Whispering Gallery Modes.
Liu, Louis W Y; Kandwal, Abhishek; Kogut, A; Eremenko, Z E; Kogut, E; Islam, M T; Dolia, R; Nosatiuk, S; Nguyen, Son T.
Afiliação
  • Liu LWY; Faculty of Engineering, Vietnamese German University, Le Lai Street, Hoa Phu Ward, Thu Dau Mot City 75000, Vietnam.
  • Kandwal A; SIAT Chinese Academy of Sciences, Shenzhen 518100, China.
  • Kogut A; O.Ya.Usikov Institute for Radiophysics and Electronics of NAS of Ukraine, 61072 Kharkov, Ukraine.
  • Eremenko ZE; O.Ya.Usikov Institute for Radiophysics and Electronics of NAS of Ukraine, 61072 Kharkov, Ukraine.
  • Kogut E; Institute of Radiophysics and Electronics, V.N.Karazin Kharkov National University, 61072 Kharkov, Ukraine.
  • Islam MT; Department of Electrical, Electronic & Systems Engineering, Universiti Kebangsaan Malaysia, Bangi 43600, Malaysia.
  • Dolia R; O.Ya.Usikov Institute for Radiophysics and Electronics of NAS of Ukraine, 61072 Kharkov, Ukraine.
  • Nosatiuk S; O.Ya.Usikov Institute for Radiophysics and Electronics of NAS of Ukraine, 61072 Kharkov, Ukraine.
  • Nguyen ST; Faculty of Engineering, Eastern International University, Binh Duong 75000, Vietnam.
Sensors (Basel) ; 20(3)2020 Feb 04.
Article em En | MEDLINE | ID: mdl-32033139
ABSTRACT
The permittivity of blood glucose is not a strong function of its concentration in microwave or millimeter-wave frequencies. Measuring glucose concentrations remains a challenge, particularly in the presence of interference caused by the ambient leaky waves. In this paper, however, we demonstrate that a near-linear correlation between the glucose concentration and the blood permittivity was noticeably observed at a whispering gallery mode resonance.

METHOD:

the proposed sensor was a vacuum suction aspirator partially wounded with a turn of the Goubau line. This arrangement enabled a fixed cylindrical volume of a skin tissue bump or glucose/water solution to be formed and used as a whispering gallery resonator for in-vivo and ex-vivo measurements.

RESULTS:

in the in-vivo study, a near-linear correlation between the glucose levels and the S21 parameters was noticeably observed at the fundamental whispering gallery resonance (i.e., at 2.18 GHz). In the ex-vivo study, a similar correlation was observed between the concentration of a glucose/water solution and the S21 parameters 56.6 GHz.

CONCLUSION:

the results of both investigations were consistent not only with the invasive measurements using the Accu-checkTM, but also with the conclusion drawn by some other research groups who have successfully measured blood glucose concentrations at millimeter-wave frequencies.